Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-23
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1786-Drive Array
Recovery
Needed
The following
drive(s) need
Automatic Data
Recovery: SCSI
port 1, SCSI ID O
Select F1 to
continue
automatic data
recovery to drive.
Select F2 to
continue without
starting automatic
data recovery
data to drive.
Or
Slot 1 Drive Array
Recovery
needed.
Automatic data
recovery
previously
aborted. The
following SCSI
drive(s) need
automatic data
recovery; SCSI
port 1; SCSI ID 0.
Select F1 to retry
Automatic Data
Recovery to
drive. Select F2
to continue
without starting
Automatic Data
Recovery to
drive.
None Interim Data Recovery
mode. Data has not been
recovered yet.
Press the F1key to start the
Automatic Data Recovery to
begin. Data will automatically
be restored to drive X now that
the drive has been replaced or
now seems to be working.
Or
Press the F2 key and the
system will continue to operate
in the Interim Data Recovery
mode.
The previously aborted version
of the 1786 POST message
will appear if the previous
rebuild attempt was aborted for
any reason. Run Drive Array
Advanced Diagnostics (DAAD)
for more information. If the
replacement drive was failed,
try using another replacement
drive. If rebuild was aborted
due to a read error from
another physical drive in the
array, back up all readable
data on the array. Run
Diagnostics Surface Analysis
to restore your data.
1787-Slot x Drive
Array Operating
in Interim
Recovery Mode.
The following
SCSI drive(s)
should be
replaced: SCSI
port (y):
SCSI ID (x)
None Hard drive X failed or cable
is loose or defective.
Following a system restart,
this message reminds you
that drive X is defective and
fault tolerance is being
used.
1. Replace drive X as soon
as possible.
2. Check loose cables.
3. Replace defective cables.
continued