Diagnostics and Troubleshooting
4-24 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
* 1788-Slot x
drive array
reports incorrect
drive
replacement. The
following SCSI
drive(s) should
have been
replaced: SCSI
port (y), SCSI
ID (x). The
following SCSI
drive(s) were
incorrectly
replaced; SCSI
port (y), SCSI
ID (z).
Select F1 to
continue-drive
array will remain
disabled.
Select F2 to reset
configuration-all
data will be lost.
None Drives are not installed in
their original positions, so
the drives have been
disabled. See note below.
Reinstall the drives correctly as
indicated.
Press the F1 key to restart the
computer with the drive array
disabled.
-Or-
Press the F2 key to use the
drives as configured and lose
all the data on them.
1788-Slot x drive
array reports
incorrect drive
replacement. The
following SCSI
drive(s) should
have been
replaced: SCSI
port (y), SCSI
ID (x). The
following SCSI
drive(s) were
incorrectly
replaced; SCSI
port (y), SCSI
ID (z).
Select F1 to
continue-drive
array will remain
disabled.
Select F2 to reset
configuration-all
data will be lost.
None Drives are not installed in
their original positions, so
the drives have been
disabled. See note below.
Reinstall the drives correctly as
indicated.
Press the F1 key to restart the
computer with the drive array
disabled.
-Or-
Press the F2 key to use the
drives as configured and lose
all the data on them.
continued