Diagnostics and Troubleshooting 
4-32  Compaq ProLiant DL360 Server Maintenance and Service Guide 
 
 
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM 
 
Table 4-4:  Memory Test Error Codes continued 
Error Code  Description  Recommended Action 
211-01 
211-02 
211-03 
211-04 
 
211-05 
 
211-89 
RAND test failed. 
Error while saving test block. 
Error while restoring test block. 
Insufficient memory to perform the 
test. 
Failed inverted pattern compare, 
but RAM was correct. 
ECC error during noise test. 
1.  Replace the memory module/board and 
retest. 
2.  Replace the system board and retest. 
214-01 
214-89 
Data error during noise test 
ECC error during testing  
1.  Replace the memory module/board and 
retest. 
2.  Replace the system board and retest. 
215  Nonfunctioning DC-DC converter 
for processor X 
Replace the DC-DC converter 
(Processor Power Module).