e. Open a command line and enter the following commands to restart RIS:
net stop binlsvc
net start binlsvc
NOTE:
The following Microsoft Knowledge base articles were
used as a reference for the previous instructions:
How to Add OEM Plug and Play Drivers to Windows
Installations
(
http://support.microsoft.com/default.aspx?scid=kb;EN-
US;254078)
How to Add Third-Party OEM Network Adapters to RIS
Installations
(
http://support.microsoft.com/default.aspx?scid=kb;EN-
US;246184).
Install Windows CCS 2003 on the compute nodes using RIS
After RIS is properly configured on the head node, you will deploy the compute nodes, the servers
that provide computational resources. Detailed instructions are located in the "Using Automated
Addition to Add Nodes section" of the Microsoft documentation
(
http://go.microsoft.com/fwlink/?LinkID=27332).
1. Begin deploying the compute nodes from the Node management section of the Compute Cluster
Administrator To-Do List. Select Add Nodes using the Automated Deployment method and follow
the prompts. Detailed instructions are located in the "Using Automated Addition to Add Nodes
section" of the Microsoft documentation (
http://go.microsoft.com/fwlink/?LinkID=27332)
2. Once all of the nodes have been deployed, from the head node, run the Compute Cluster
Administrator and select the Node Management screen. All of the compute nodes report a
Pending Approval state.
3. Highlight all of the compute nodes and double click Approve. The nodes change to a Paused
state.
4. Highlight all of the compute nodes and double-click Resume. The nodes change to a Ready state.
5. Add administrators and users to your cluster using the User Management wizard in the Compute
Cluster Administrator.
Manually update drivers
If you have installed other devices, such as InfiniBand interconnect cards, you may need to manually
install the drivers to support these devices. Depending on the driver support provided, the installation
method may vary. Refer to the documentation for the device for exact installation procedures.
However, the following are possible solutions:
Remote Device Installation—Some vendors provide a utility to remotely install devices. Check your
vendor documentation to see if this is available.
Integration into RIS image—It may be possible to integrate the drivers into the RIS image prior to
deployment. Refer to the Microsoft Knowledge Base article listed above for suggestions.
Manual Installation—You may need to login in directly to each compute node (using Remote
Desktop) and manually install and configure the drivers.
Run Command Feature—The Compute Cluster Administrator has a feature called Run Command
that allows you to execute a command line executable across all nodes in the cluster.
9

Other manuals for HP ProLiant DL360p

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL360p and is the answer not in the manual?

HP ProLiant DL360p Specifications

General IconGeneral
Max Processors2
Form Factor1U Rack
MemoryUp to 768GB DDR3
Memory Slots24
RAID SupportHP Smart Array P420i Controller
Network4 x 1Gb Ethernet ports
Power Supply460W, 750W
ManagementHP iLO (Integrated Lights-Out)
Storage8 SFF or 4 LFF

Related product manuals