Removal and Replacement Procedures 19
Removing the Access Panel
WARNING: To reduce the risk of personal injury from hot
surfaces, allow the drives and the internal system components to
cool before touching them.
CAUTION: Do not operate the server for long periods without
the access panel. Operating the server without the access panel results
in improper airflow and improper cooling that can lead to thermal
damage.
1. Power down the server if performing a non-hot-plug installation or
maintenance procedure.
2. Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page 16
).
3. Lift up on the hood latch handle and remove the access panel.
Hot-Plug SCSI Hard Drive
To remove the component:
CAUTION: To prevent improper cooling and thermal damage,
do not operate the server unless all bays are populated with either a
component or a blank.
1. Determine the status of the hard drive from the hot-plug hard drive LEDs
("Hot-Plug SCSI Hard Drive LEDs" on page 95
).
2. Back up all server data on the hard drive.
HP CONFIDENTIAL
File Name: 291916-6.doc Last Saved On: 2/5/04 2:26 PM