Removal and replacement procedures 46
3.
Do one of the following:
o Extend the server from the rack (on page 30).
o Remove the server from the rack (on page 32).
4. Remove the access panel ("Access panel" on page 35).
5. Remove the air baffle ("Air baffle" on page 38).
6. Open the DIMM slot latches.
7. Remove the DIMM.
To replace the component, reverse the removal procedure.
Heatsink blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1. Power down the server (on page 29).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 30).
o Remove the server from the rack (on page 32).
4. Remove the access panel ("Access panel" on page 35).