Connectors, switches, and LEDs 106
System board LED indicators
Item Indicator Status Description
1 Heat sink failure Amber Heat sink error detected
2 DC power on Green System is turned on.
3 Management controller
heartbeat
Blinking green Baseboard Management Controller (BMC) activity
4 System/processor over
temperature (OTP)
Amber A system or processor temperature sensor has been
breached.
5 Standby power Green System is in standby mode.
6 System fan failure Amber System fan error detected
7 Memory module failure Amber Memory module error detected