Component identification  87 
Item  LED  Status  Definition 
   
Flashing green  The drive is rebuilding or performing a RAID migration, strip size 
migration, capacity expansion, or logical drive extension, or is 
erasing. 
   
Flashing 
amber/green 
The drive is a member of one or more logical drives and predicts 
the drive will fail. 
   
Flashing amber  The drive is not configured and predicts the drive will fail. 
   
Solid amber  The drive has failed. 
   
Off  The drive is not configured by a RAID controller. 
The blue Locate LED is behind the release lever and is visible when illuminated. 
 
 
IMPORTANT: The HP Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode. 
It cannot be enabled in Legacy BIOS Boot Mode. If the B140i controller is disabled, drives 
connected to the system board Mini-SAS connectors operate in AHCI or Legacy mode. Under this 
condition: 
•  The drives cannot be a part of a hardware RAID or a logical drive. 
•  The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled. 
Use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities ("HP UEFI System Utilities" on 
page 72) to enable or disable the B140i controller (System Configuration → BIOS/Platform 
Configuration (RBSU) → System Options → SATA Controller Options → Embedded SATA 
Configuration).