EasyManua.ls Logo

HP ProLiant ML350e - Page 75

HP ProLiant ML350e
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware options installation 75
o
For tower models, install the bezel ("Install the rack bezel" on page 25).
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
Installing the B120i cache module
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 22).
o For rack models, if installed, remove the security bezel (on page 24).
2. Power down the server (on page 22).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 27).
5. Remove the access panel (on page 25).
6. Remove the PCI air baffle (on page 28), if installed.
7. Remove any PCI cards installed in PCI slots 3, 4, 5 and 6.
8. Install the FBWC module in the cache module connector on the system board.
9. Install the FBWC capacitor pack.
CAUTION: When connecting or disconnecting the capacitor pack cable, the connectors on the
cache module and cable are susceptible to damage. Avoid excessive force and use caution to
avoid damage to these connectors.

Other manuals for HP ProLiant ML350e

Related product manuals