Verify that the diagnostic tests are
not running. Re-enable the port us-
ing the portEnable command.
Receiving light or carrier, but
not online
Slow blinking amber
(2 seconds)
Check the management interface
and the error log for details on the
cause of the failure. Contact HP
technical support if necessary.
Port failure
Fast blinking amber
(1/2 second)
No action required.OnlineSteady green
No action required.
Online but segmented (loopback
cable or incompatible switch)
Slow blinking green
(2 seconds)
No action required.Internal loopback (diagnostic)
Fast blinking green
(1/2 second)
No action required.
Online; frames flowing through
port
Flickering green
Nonport side LED activity for FCoE Converged Network
Switches
Figure 29 shows the LEDs on the nonport side of the switch. See Figure 8 on page 26 for power
supply and fan assembly locations.
4. Fan assembly #2 status LED1. Power supply #2 status LED
5. Fan assembly #1 status LED2. Power supply #1 status LED
3. Fan assembly #3 status LED
Figure 29 Nonport side LEDs on the FCoE Converged Network Switch
8-Gb SAN Switch hardware reference manual 67