Disconnect-Volume Operation
If this operation is performed from Remote Web Console, this logged information indicates that the
Disconnect-Volume operation was only requested, but not finished. However, if this operation is
performed from CFL Extension (or if this logged information appears between the CflSet Start operation
and the CflSet End operation), this logged information indicates that the Disconnect-Volume operation
was finished.
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Ext Stor],Disconnect-Volume,,Normal end,,,Seq.=xxxxxx
+{Group,Result}=[{E1-1,Normal End},{E1-2,Error(605-3003)},{E1-3,Normal End},
{E1-4,Normal End}],Num of Groups=XXX
[Ext Stor]
HP XP External Storage Software function
Disconnect-Volume
Disconnect-Volume operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 91.
Table 91 Disconnect-Volume Operation
DescriptionItem
The group number of the disconnected external volume.Group
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
Result
The number of external volume groups that contain the disconnected external volume.Num. of Groups
DividePathGroup Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,[UVM],DividePathGroup,,Normal
end,,,Seq.=xxxxx
+{PathGroup,NewPathGroup,ExGroup,Result}=[{1,11,E1-11,Normal
end},{1,12,E1-21,Normal end},
{2,21,E2-11,Normal end}],Num. of Volumes=3
[Ext Stor]
HP XP External Storage Software function
DividePathGroup
XP External Storage Software Function136