HP StorageWorks
P9000 Data Exchange Code Converter User
Guide
Abstract
This guide describes and provides instructions for installing and using the Data Exchange feature of the HP XP
P9000 storage systems.
Part Number: T1620-96017
First edition: October 2010

Table of Contents

Other manuals for HP StorageWorks P9000

Questions and Answers

  • A
    Ashley RichardsAug 30, 2025
    What to do if HP Storage returns DATASET_ERROR_DATASET_NOT_FOUND?
    • J
      Joe HigginsAug 30, 2025
      If you encounter a DATASET_ERROR_DATASET_NOT_FOUND error, verify that the actual dataset name matches the specified dataset name. To check the dataset name, you can use the MF-File list command in the FCU Help menu or the VTOC dump data on the mainframe host.
  • C
    courtneyjonesAug 25, 2025
    How to fix HP Storage Remote Web Console when it hangs?
    • T
      Thomas SmithAug 25, 2025
      If the HP Storage Remote Web Console hangs or Cnt Ac-J Z operations malfunction, first ensure the issue isn't with your computer, Ethernet hardware, or software by restarting the computer. Verify that all Cnt Ac-J Z requirements are met, and that the primary/secondary systems and remote copy connections are powered on with operational NVS and cache. Double-check all entered values and parameters for accuracy in the Remote Web Console. Avoid using Performance Monitor during these operations.
  • D
    Daniel SotoSep 23, 2025
    What to do if line is longer than the maximum length in HP StorageWorks P9000 Storage?
    • A
      Amanda GarnerSep 23, 2025
      If a line exceeds the maximum length in HP Storage, modify the definition statement to fit within 120 columns, and then re-execute the process.
  • G
    goodrobertSep 2, 2025
    What causes DATASET_ERROR_VOLUME_DEFINED_READ_ONLY in HP Storage?
    • G
      Gary HouseSep 2, 2025
      If you encounter the DATASET_ERROR_VOLUME_DEFINED_READ_ONLY error, ensure that the target dataset for an open-system write operation is on a 3390-3A/C volume.
  • K
    Kirsten PetersenSep 6, 2025
    What to do if there is a pinned track on a HP StorageWorks P9000 Business Copy volume?
    • C
      Chelsea ClarkSep 6, 2025
      Contact HP Technical Support for assistance in recovering pinned tracks.
  • C
    Cheryl GarnerAug 31, 2025
    What causes FCU errors when accessing an FCU parameter definition file in HP StorageWorks P9000 Storage on Windows?
    • C
      Casey RosalesSep 1, 2025
      If FCU reports errors when accessing an FCU parameter definition file on Windows systems, remove all space lines from the FCU parameter definition files. FCU versions 01-01-36 and later do not support space lines, while FCU versions 01-01-24 and earlier supported space lines when run without the GUI.
  • D
    Derrick CampbellAug 28, 2025
    How to recover from HP StorageWorks P9000 Storage Initial Copy Failed error?
    • A
      angela63Aug 28, 2025
      If the primary HP Storage system suspended a pair during the initial copy operation, indicating the data on the S-VOL isn't identical to the P-VOL (possibly due to an invalid track format), release the pair from the primary storage system. Clear all error conditions at the primary storage system, the P-VOL, the secondary storage system, and the S-VOL. Reformat failed tracks using ICKDSF, and restart the initial copy operation using the Add Pair dialog box.
  • J
    Joe SanchezSep 8, 2025
    How to resolve HP Storage 'Communication Failed'?
    • D
      Diane DavisSep 8, 2025
      If 'Communication Failed' appears, the primary system connected to the secondary system, but a logical communication timeout occurred. Verify that the secondary system port and network relay devices (cables and switches) are properly configured and functioning.
  • A
    Adam LeonardSep 4, 2025
    How to fix missing LUN mapping information in HP StorageWorks P9000 mapping reports?
    • K
      kathryn89Sep 4, 2025
      Missing LUN mapping information in the mapping reports can occur if read permission has not been assigned on corresponding OS device special files. Assign read permission to device special files to resolve this.
  • W
    Walter BraunAug 27, 2025
    How to troubleshoot HP StorageWorks P9000 Storage Communication Failed error?
    • D
      Diana GomezAug 27, 2025
      If communication fails on your HP Storage, meaning the primary system connects to the secondary system but a logical communication timeout occurs, ensure that the secondary system port and network relay devices (cables, switches) are properly configured and functioning.

Summary

1 Overview of HP StorageWorks Data Exchange Software Code Converter

Overview of Code Converter

General introduction to the Data Exchange Code Converter functionality and its purpose.

Data Exchange Code Converter Process

Describes the operational flow and components involved in the Data Exchange Code Converter.

2 Code Converter Functions

Alphanumeric Character Conversion Function

Details the process of converting alphanumeric character data, focusing on single-byte codes.

Double-byte Character Conversion Function

Explains double-byte character conversion, including mixed single and double-byte data.

Numeric Conversion Function

Covers the conversion of numeric data fields, including process flow.

3 System Requirements and Installation

System Requirements

Lists the necessary hardware, software, and release notes for the Code Converter.

Installation Media for UNIX-based Systems

Details the files and their locations provided on the installation media for UNIX.

Installing and Uninstalling for UNIX Systems

Step-by-step guide for installing, uninstalling, and upgrading on UNIX systems.

License Key Input

Explains how to input the license key required for Code Converter operation.

4 Using Data Exchange Code Converter

Data Exchange Code Converter User Process Flow

Illustrates the user's workflow for performing data conversion operations.

Database Data File Record Format

Describes the supported record formats and field positions for data files.

5 Mainframe to Open System (MTO) Character Code Conversion

Overview of Character Code Conversion

Introduces MTO conversion, including EBCDIC to ASCII and IBM Traditional Chinese to Big5.

Alphanumeric Field Conversion (CHAR:OPK4)

Details the specific conversion of alphanumeric fields in MTO.

6 Open System to Mainframe (OTM) Character Code Conversion

Overview

Introduces OTM conversion, including ASCII to EBCDIC and Big5 to IBM Traditional Chinese.

Customizing the Code Conversion Table

Explains how to customize the code conversion table for OTM.

7 Numeric Conversion

Packed Decimal Conversion (NUM:OPA1)

Details the conversion of packed decimal numeric data.

Zoned Decimal Conversion (NUM:OPA2)

Explains the process for converting zoned decimal numeric data.

8 Customizing the Code Conversion Table

Operation Overview

Provides a high-level overview of the code conversion table customization process.

Definition Statement Syntax

Describes the syntax rules for defining conversion statements used in customization.

Command Syntax for UNIX Systems

Explains the command syntax for customizing tables on UNIX systems.

9 Troubleshooting

Error Codes

Lists and explains common error codes and their meanings.

ccnv Messages

Details the format and interpretation of messages generated by the ccnv utility.

Calling HP Technical Support

Provides guidance on what information to gather before contacting HP support.

10 Support and Other Resources

Related Documentation

Lists other relevant HP documents for further information.

HP Technical Support

Information on how to obtain technical support from HP.

A Edit Option File

B HOSTBIG5

C EBCDIC-ASCII Code Conversion

Glossary

HP StorageWorks P9000 Specifications

General IconGeneral
RAID SupportRAID 0, 1, 5, 6, 10
InterfaceFibre Channel, iSCSI, FCoE
Form FactorRack-mountable
ModelP9000
Operating System CompatibilityWindows, Linux, VMware, HP-UX
Host InterfaceFibre Channel, iSCSI, FCoE
Drive InterfaceSAS, SSD
Drive Types SupportedSSD, SAS
RedundancyRedundant controllers, power supplies, and fans
Management SoftwareHP StorageWorks Command View

Related product manuals