HP StorageWorks
P9000 Remote Web Console Messages
Abstract
This document lists the error codes and error messages for HP StorageWorks P9000 Remote Web Console for P9000 disk
arrays, and provides recommended action for the error conditions.
HP Part Number: AV400-96351
Published: January 2011
Edition: Third

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers

  • J
    Jeffery WilliamsSep 12, 2025
    What to do if HP StorageWorks P9000 - Disk Arrays Storage shows 'Port number invalid' error?
    • D
      Doris JosephSep 12, 2025
      If you encounter a 'Port number invalid' error on HP Storage, delete the failed path. Then, check the specified port number and the cable connection before retrying the operation.
  • H
    hmorenoAug 25, 2025
    Why does my HP StorageWorks P9000 - Disk Arrays host not reboot after a hard shutdown?
    • P
      Paul ClarkAug 25, 2025
      If the host does not reboot properly after a hard shutdown, wait three minutes to allow the disk array's internal timeout process to purge queued commands. If the host restarts while the disk array is processing queued commands, the host may not reboot successfully.
  • B
    Brian AndersonAug 25, 2025
    What to do if HP StorageWorks P9000 - Disk Arrays Storage host detects a parity error?
    • A
      Amber AndersonAug 26, 2025
      If the host detects a parity error, check the FCA and make sure it was installed properly. Reboot the host.
  • J
    Joseph WeaverSep 23, 2025
    Why can't I change the CLPR name on my HP StorageWorks P9000 - Disk Arrays Storage?
    • D
      Dr. Sean Davis IIISep 23, 2025
      The CLPR name cannot be changed if the name you entered is already in use or is reserved by the system. To resolve this issue, enter another name.
  • S
    Sheena VanceSep 12, 2025
    How to resolve a 'Communication error' on HP Storage?
    • M
      Miss Michele WolfSep 12, 2025
      If you're experiencing a 'Communication error' with HP Storage, where a timeout error occurred in the path between the primary and secondary systems, delete the failed path and retry.
  • S
    Shelley CrawfordSep 18, 2025
    How to fix 'This path was not established' error on HP Storage?
    • N
      Nicole PhillipsSep 18, 2025
      If the HP Storage shows 'This path was not established', delete the failed path. You may need to change the minimum paths setting or delete the secondary system in order to delete the path. After deletion finishes, add the path and the secondary system by using the Add Path or Add DKC command.
  • D
    Dylan RobinsonSep 5, 2025
    What to do if the HP StorageWorks P9000 - Disk Arrays primary system suspended a pair during the initial copy operation?
    • C
      Charles MckinneySep 5, 2025
      If the HP Storage primary storage system suspended this pair during the initial copy operation because the data on the S-VOL is not identical to the data on the P-VOL, release the pair from the primary storage system. Clear all error conditions at the primary storage system, P-VOL, secondary storage system, and S-VOL. Restart the initial copy operation using the Paircreate dialog box.
  • M
    Malik SmithSep 6, 2025
    Why did the HP StorageWorks P9000 - Disk Arrays Storage primary system suspend all Cnt Ac-J pairs when powered off?
    • C
      Caleb BrownSep 6, 2025
      If the HP Storage primary storage system suspended all Cnt Ac-J pairs because the primary storage system was powered off, no action is needed. The primary storage system automatically restores these Cnt Ac-J pairs when it is powered back on.
  • S
    Steven MeyersSep 18, 2025
    What to do if hardware failures cause pairs to be suspended on HP Storage?
    • K
      Kimberly MartinezSep 18, 2025
      If primary or secondary system hardware failures affecting the cache memory and the shared memory of the primary or secondary system may also cause the pairs to be suspended on your HP Storage, remove the hardware blockade or failure according to the SIM. Restore the failed volume pairs (Pairresync). If a failure occurs during execution of the RAID Manager horctakeover command, secondary volumes in SSWS pair status may remain in the master journal. If these volumes remain, execute the pairresync -swaps command on the secondary volumes whose pair status is SSWS (pairresync is the RAID Manager command for resynchronizing pair and -swaps is a swap option. This operation changes all volumes in the master journal to primary volumes. After this operation, restore the volume pairs (Pairresync).
  • C
    Carol MendozaAug 30, 2025
    What to do if a Business Copy Z error message is displayed on HP StorageWorks P9000 - Disk Arrays Storage Remote Web Console?
    • D
      davidcooperAug 30, 2025
      Select the failed volume in the Preview List on the Pair Operation window, right-click to display the menu, and then click Error Detail.

Summary

Message (part code group 0 nnn)

Part code 0001

Details error messages and recommended actions for part code 0001.

Part code 0002

Details error messages and recommended actions for part code 0002.

Part code 0003

Details error messages and recommended actions for part code 0003.

Message (part code group 1 nnn)

Part code 1005

Details error messages and recommended actions for part code 1005.

Message (part code group 2 nnn)

Part code 2005

Details error messages and recommended actions for part code 2005.

Message (part code group 3 nnn)

Part code 3005

Details error messages and recommended actions for part code 3005.

Message (part code group 4 nnn)

Message (part code group 5 nnn)

Message (part code group 6 nnn)

Message (part code group 7 nnn)

Message (part code group 8 nnn)

Message (part code group 9 nnn)

Message (part code group 10 nnn)

Message (part code group 20 nnn)

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
Form FactorRack-mountable
ModelHP StorageWorks P9000
TypeDisk Array
CategoryStorage
Drive TypeSSD, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Host InterfaceFibre Channel, FCoE, iSCSI
ConnectivityFibre Channel, FCoE, iSCSI
Cache MemoryUp to 512 GB
ControllersDual controllers
Management SoftwareHP StorageWorks Command View
Redundancycontrollers, power supplies, and fans
Operating Humidity20 to 80% relative humidity, non-condensing