Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WInstall the necessary program products
in the RCU.
The operation failed, because the
following program products were not
installed in the RCU.
• Continuous Access Synchronous
688936005
WConfirm the quorum disk ID, serial
number of RCU, and quorum disk.
The operation failed, because the
quorum disk registered in the specified
quorum disk ID was not registered in the
quorum disk ID of RCU, or it was
registered in the other quorum disk ID.
688946005
WConfirm the quorum disk ID status.The operation failed, because a quorum
disk was not registered in the specified
quorum disk ID.
688996005
WConfirm the quorum disk ID of the
specified pair.
The operation failed, because the
specified quorum disk ID was different
from the one used by the specified pair.
689006005
WCheck the microcode version of the
storage system.
The operation failed, because the current
microcode version does not support the
capacity of the specified M-VOL.
780016005
WCheck the microcode version of the
storage system.
The operation failed, because the current
microcode version does not support the
capacity of the specified R-VOL.
780026005
Part code 6007
Table 51 Error codes (part code 6007)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WInstall Continuous Access Synchronous
or Continuous Access Synchronous Z.
Continuous Access Synchronous or
Continuous Access Synchronous Z is not
installed.
50746007
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60006007
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60026007
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60126007
WIf the same problem persists despite
retrying, please contact HP Technical
Support.
The SVP is busy. Please wait for a while,
and then retry the operation.
60226007
WIf the same problem persists despite
retrying, please contact HP Technical
Support.
The SVP is busy. Please wait for a while,
and then retry the operation.
60236007
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60246007
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60366007
EIf the problem persists despite retrying,
please contact HP Technical Support.
A time-out error occurred.80016007
Part code 6007 157

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals