5 Message (part code group 3nnn)
This chapter includes the error messages with the part code 3005 to 3305.
Part code 3005
Table 31 Error codes (part code 3005)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the setting of the specified
volumes.
The specified volume contains Snapshot
pair.
19103005
WCheck the setting of the specified
volumes.
The specified volumes contain
Pool-VOLs.
19113005
EPlease contact HP Technical Support.The status of the disk subsystem requires
maintenance (for example, the
subsystem is blocked, the shared
memory is inconsistent, or some other
factor).
20113005
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem.
20153005
WWait for a while, then retry the
operation.
Copying is in progress for Remote
Copy, Business Copy, Business Copy
Z, Snapshot, or Auto LUN pairs.
20853005
WRelease the configuration definition, then
retry the operation.
The configuration of Remote Copy,
Business Copy, Business Copy Z,Auto
LUN, or Snapshot has been defined.
20863005
WTake the storage system offline from the
host.
The storage system is online to the
mainframe host.
20873005
WAdd an alternative path.The Remote Copy pair is suspended.20883005
WMake sure that there is an alternative
path from the MCU.
The corresponding CHA might contain
the last path between the MCU and
RCU of Remote Copy.
20893005
WRelease the setting(s) or stop the I/O(s),
then retry the operation.
Business Copy, Business Copy Z, or
Snapshot setting exists.
20903005
WStop the backup server, and then retry
the operation.
The backup server of Business Copy,
Business Copy Z, or Snapshot is
running.
20913005
WSplit the Business Copy, Business Copy
Z, or Snapshot pairs.
Some Business Copy, Business Copy Z,
or Snapshot pairs exist.
20923005
WResynchronize the Business Copy,
Business Copy Z, or Snapshot pairs.
Some Business Copy, Business Copy Z,
or Snapshot pairs exist.
20933005
WChange the status of the volumes to
Simplex.
Some Business Copy, Business Copy Z,
or Snapshot pairs exist.
20943005
76 Message (part code group 3nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers: