Table 64 Error codes (part code 8005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EConfirm the setting status of the current
system disk option. For the functions that
could not be set, add a system disk or
restore the blocked system disk, then
retry the operation.
There are functions that cannot change
the system disk option due to one of the
following reasons:
The system disk capacity is
insufficient.
The system disk is blocked.
657838005
EIf this problem persists, please contact
HP Technical Support.
An error occurred on the DKC side.687618005
WInstall the required program product.This functionality is not available.
Encryption License Key is required.
687628005
WUse the correct encryption key.The serial number of the encryption key
does not match.
687668005
WCheck the specified parity group.The specified parity group is not
mounted.
687858005
WCheck the status of the specified parity
group.
The specified parity group is not
blocked.
687868005
Part code 8105
Table 65 Error codes (part code 8105)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WSelect another volume.The specified volume cannot be set as a
command device or a component of a
LUSE volume, because it is being used
as the volume of Remote Copy, Business
Copy, Auto LUN, or Snapshot.
10028105
WThe configuration information has been
already changed.
Check the settings, and request the
setting of the configuration information
again.
You are trying to set multiple paths to the
same volume from one group.
10038105
WThe configuration information has been
already changed.
Check the settings, and request the
setting of the configuration information
again.
Multiple volumes are specified to a single
port, group or LUN combination.
10048105
WCheck the settings, then retry the
operation.
The following volumes cannot be
specified when you change the path
configurations:
Volumes that do not exist
Volumes other than the top LUs in
expanded LUs
Volumes reserved by Auto LUN
System Disk volume
10058105
Part code 8105 259

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals