3 Message (part code group 1nnn)
This chapter includes the error messages with the part code 1005 to 1310.
Part code 1005
Table 25 Error codes (part code 1005)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WSelect another volume.The specified volume cannot be set as a
command device or a component of a
LUSE volume, because it is being used
as the volume of Remote Copy, Business
Copy, Auto LUN, or Snapshot.
10021005
WThe configuration information has been
already changed.
Check the settings, and request the
setting of the configuration information
again.
You are trying to set multiple paths to the
same volume from one group.
10031005
WThe configuration information has been
already changed.
Check the settings, and request the
setting of the configuration information
again.
Multiple volumes are specified to a single
port, group or LUN combination.
10041005
WCheck the settings, then retry the
operation.
The following volumes cannot be
specified when you change the path
configurations:
• Volumes that do not exist
• Volumes other than the top LUs in
expanded LUs
• Volumes reserved by Auto LUN
• System Disk volume
10051005
WCheck the setting.Failed to remove the path. The specified
path is the last path of the volumes used
for Remote Copy, Business Copy, Auto
LUN, or Snapshot.
10071005
WThe configuration information has been
changed already. Check the settings,
and request the setting of the
configuration information again.
The emulation type of the volumes is not
for open systems, or the volumes are not
mounted.
10091005
WIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
10101005
WThe configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The specified port does not exist. Or the
specified port type is not Fibre port.
10181005
WThe configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Invalid LUN.10201005
Part code 1005 53

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals