EasyManuals Logo

HP StorageWorks P9000 - Disk Arrays User Manual

HP StorageWorks P9000 - Disk Arrays
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background image
Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WConfirm the relationship status of
Compatible FlashCopy and the pair
status of Continuous Access Synchronous
Z.
The operation failed, because the
specified primary data volume was as
follows:
• This volume was used as T-VOL of
Compatible FlashCopy.
• This volume was used as M-VOL of
Continuous Access Synchronous Z,
and it was suspended by either of the
following settings:
• It was a pair of synchronous
consistency group.
• It was a pair that the "Cylinder" was
set to "Difference Management."
688876505
WConfirm the relationship status of the
Compatible FlashCopy.
The operation failed, because the
specified "primary data volume" was
used as T-VOL of Compatible FlashCopy
that might be in the abnormal state due
to a failure.
688886505
WCheck the specified journal.The specified journal cannot be used.780036505
WCheck the specifed consistency group.The specified consistency group cannot
be used.
780046505
WCheck the specified capacity of the
primary data volume and the current
microcode version.
The operation failed because the
specified capacity of the primary data
volume is not supported by the current
microcode version.
780506505
WCheck the specified capacity of the
secondary data volume and the current
microcode version.
The operation failed because the
specified capacity of the secondary data
volume is not supported by the current
microcode version.
780516505
EPlease contact HP Technical Support.The operation failed. The Mainframe
Fibre CHA of RCU is not mounted or all
the Mainframe Fibre CHA are blocked.
780666505
Part code 6507
Table 54 Error codes (part code 6507)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the settings, and retry the
operation.
Two or more commands which were not
able to be processed were demanded.
50366507
EIf the problem persists despite retrying,
please contact HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
60126507
EIf the problem persists despite retrying,
please contact HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
60366507
Part code 6507 203

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
Form FactorRack-mountable
ModelHP StorageWorks P9000
TypeDisk Array
CategoryStorage
Drive TypeSSD, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Host InterfaceFibre Channel, FCoE, iSCSI
ConnectivityFibre Channel, FCoE, iSCSI
Cache MemoryUp to 512 GB
ControllersDual controllers
Management SoftwareHP StorageWorks Command View
Redundancycontrollers, power supplies, and fans
Operating Humidity20 to 80% relative humidity, non-condensing

Related product manuals