8 Message (part code group 6nnn)
This chapter includes the error messages with the part code 6005 to 6810.
Part code 6005
Table 50 Error codes (part code 6005)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
50136005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
50996005
WRefresh the window, then retry the
operation.
If the same problem persists despite
retrying, please contact HP Technical
Support.
This function does not support the
specified port.
51456005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60006005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
60126005
WIf the same problem persists despite
retrying, please contact HP Technical
Support.
The SVP is busy. Please wait for a while,
and then retry the operation.
60236005
WIf the problem persists despite retrying,
please contact HP Technical Support.
Time out error.80006005
WIf the problem persists despite retrying,
please contact HP Technical Support.
Time out error.80016005
WIf the problem persists despite retrying,
please contact HP Technical Support.
Time out error.81006005
WWait for a while, and then refresh the
window and confirm the pair status has
been changed properly.
If the pair status is not changed despite
refreshing the window, check the MCU
or RCU configuration and the condition
of the paths between the MCU and RCU.
The storage system has accepted the
request normally, however the processing
requires some time. Wait for a while,
then refresh the window and confirm the
pair status has been changed properly.
If the pair status is not changed despite
refreshing the window, check the MCU
or RCU configuration and the condition
of the paths between the MCU and RCU.
81046005
WRetry the operation.Please retry operation.87006005
WA logical path does not exist between
the MCU and the RCU. Check the path
status on RCU Status dialog box, and
reestablish the paths with Edit Path.
Logical Path between the MCU and the
RCU is not active.
87016005
WRefresh the window, and check whether
the specified volume is a M-VOL.
The specified volume is not a M-VOL.87026005
Part code 6005 135

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
Form FactorRack-mountable
ModelHP StorageWorks P9000
TypeDisk Array
CategoryStorage
Drive TypeSSD, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Host InterfaceFibre Channel, FCoE, iSCSI
ConnectivityFibre Channel, FCoE, iSCSI
Cache MemoryUp to 512 GB
ControllersDual controllers
Management SoftwareHP StorageWorks Command View
Redundancycontrollers, power supplies, and fans
Operating Humidity20 to 80% relative humidity, non-condensing