EasyManuals Logo

HP StorageWorks P9000 - Disk Arrays User Manual

HP StorageWorks P9000 - Disk Arrays
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #156 background imageLoading...
Page #156 background image
Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the emulation type of the volume.The operation failed, because the
emulation type of the specified volume
was not OPEN -V.
688746005
WSelect another volume, or release the
LUSE setting.
The operation failed, because the
specified volume was a LUSE volume.
688756005
ESelect a parity group of an external
volume that is composed of a single
LDEV.
The operation failed, because the parity
group of the specified external volume
was composed of two or more LDEVs.
688766005
WSelect another volume, or release the
Business Copy setting.
The operation failed, because the
specified volume was a reserved volume
of Business Copy.
688776005
WSelect another volume, or release the
journal volume setting.
The operation failed, because the
specified volume was a journal volume.
688786005
ESelect another volume, or release the
pool volume setting.
The operation failed, because the
specified volume was a pool volume.
688796005
ESelect another volume, or release the
Auto LUN setting.
The operation failed, because the
specified volume was used for Auto LUN.
688806005
WSelect another volume.The operation failed, because the
specified volume was used as a system
disk.
688816005
WCheck the following conditions on the
external volume specified for the quorum
disk.
If it is blocked.
If a path is defined.
The operation failed, because the
quorum disk was inaccessible.
688826005
WCheck the serial number of the quorum
disk.
The operation failed, because the
specified serial number was different
from the serial number of the quorum
disk.
688836005
WCheck the status of the quorum disk.The operation failed, because the
quorum disk was blocked.
688896005
WSpecify the serial number of RCU and
retry the operation.
The operation failed, because the
specified serial number was not RCU but
MCU.
688906005
WConfirm the serial numbers of MCU and
RCU, and the quorum disk ID.
The operation failed, because the
following specified parameters did not
match the information in the quorum
disk.
Serial number of MCU
Serial number of RCU
Quorum disk ID
688916005
156 Message (part code group 6nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals