EasyManua.ls Logo

HP StorageWorks P9000 - User Manual

HP StorageWorks P9000
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HP StorageWorks
P9000 Data Exchange Code Converter User
Guide
Abstract
This guide describes and provides instructions for installing and using the Data Exchange feature of the HP XP
P9000 storage systems.
Part Number: T1620-96017
First edition: October 2010

Table of Contents

Other manuals for HP StorageWorks P9000

Questions and Answers

  • S
    Stephen RodgersSep 10, 2025
    How to resolve 'Communication error' on HP StorageWorks P9000?
    • K
      Kimberly CastilloSep 12, 2025
      If a 'Communication error' occurs, which means a timeout error happened in the path between the primary and secondary systems, delete the failed path and retry.
  • A
    Ashley RichardsAug 30, 2025
    What to do if HP Storage returns DATASET_ERROR_DATASET_NOT_FOUND?
    • J
      Joe HigginsAug 30, 2025
      If you encounter a DATASET_ERROR_DATASET_NOT_FOUND error, verify that the actual dataset name matches the specified dataset name. To check the dataset name, you can use the MF-File list command in the FCU Help menu or the VTOC dump data on the mainframe host.
  • W
    Walter BraunAug 27, 2025
    How to troubleshoot HP StorageWorks P9000 Storage Communication Failed error?
    • D
      Diana GomezAug 27, 2025
      If communication fails on your HP Storage, meaning the primary system connects to the secondary system but a logical communication timeout occurs, ensure that the secondary system port and network relay devices (cables, switches) are properly configured and functioning.
  • C
    Christopher ReyesSep 6, 2025
    What to do if HP StorageWorks P9000 Storage Remote Web Console hangs?
    • J
      Jeffrey MillsSep 6, 2025
      If the HP Storage Remote Web Console hangs, ensure the issue isn't with your computer, Ethernet hardware, or software. Restart the computer, which won't affect ongoing Cnt Ac-J operations. Verify all Cnt Ac-J requirements are met, and that primary/secondary systems and remote copy connections are powered on with operational NVS and cache. Double-check entered values and parameters for accuracy on the Remote Web Console, such as the secondary system S/N, path parameters, and P-VOL/S-VOL IDs. Avoid using Performance Monitor.
  • J
    Joe SanchezSep 8, 2025
    How to resolve HP Storage 'Communication Failed'?
    • D
      Diane DavisSep 8, 2025
      If 'Communication Failed' appears, the primary system connected to the secondary system, but a logical communication timeout occurred. Verify that the secondary system port and network relay devices (cables and switches) are properly configured and functioning.
  • C
    Cheryl GarnerAug 31, 2025
    What causes FCU errors when accessing an FCU parameter definition file in HP StorageWorks P9000 Storage on Windows?
    • C
      Casey RosalesSep 1, 2025
      If FCU reports errors when accessing an FCU parameter definition file on Windows systems, remove all space lines from the FCU parameter definition files. FCU versions 01-01-36 and later do not support space lines, while FCU versions 01-01-24 and earlier supported space lines when run without the GUI.
  • G
    goodrobertSep 2, 2025
    What causes DATASET_ERROR_VOLUME_DEFINED_READ_ONLY in HP Storage?
    • G
      Gary HouseSep 2, 2025
      If you encounter the DATASET_ERROR_VOLUME_DEFINED_READ_ONLY error, ensure that the target dataset for an open-system write operation is on a 3390-3A/C volume.
  • K
    Kirsten PetersenSep 6, 2025
    What to do if there is a pinned track on a HP StorageWorks P9000 Business Copy volume?
    • C
      Chelsea ClarkSep 6, 2025
      Contact HP Technical Support for assistance in recovering pinned tracks.
  • K
    Kenneth Carey IISep 10, 2025
    What to do if HP Storage reports 'Program Error'?
    • H
      hpalmerSep 10, 2025
      If a 'Program Error' is detected, delete the path by using the Delete Path or Delete DKC command, and then add the path and the secondary system again by using the Add Path or Add DKC command.
  • B
    Bryan AlexanderSep 22, 2025
    What to do if cannot output characters for code conversion table due to error encountered in HP Storage?
    • C
      Cynthia TaylorSep 22, 2025
      If the HP Storage system cannot output characters for the code conversion table due to an error, check the preceding error message to determine the cause of the error, and then re-execute the process.

Summary

1 Overview of HP StorageWorks Data Exchange Software Code Converter

Overview of Code Converter

General introduction to the Data Exchange Code Converter functionality and its purpose.

Data Exchange Code Converter Process

Describes the operational flow and components involved in the Data Exchange Code Converter.

2 Code Converter Functions

Alphanumeric Character Conversion Function

Details the process of converting alphanumeric character data, focusing on single-byte codes.

Double-byte Character Conversion Function

Explains double-byte character conversion, including mixed single and double-byte data.

Numeric Conversion Function

Covers the conversion of numeric data fields, including process flow.

3 System Requirements and Installation

System Requirements

Lists the necessary hardware, software, and release notes for the Code Converter.

Installation Media for UNIX-based Systems

Details the files and their locations provided on the installation media for UNIX.

Installing and Uninstalling for UNIX Systems

Step-by-step guide for installing, uninstalling, and upgrading on UNIX systems.

License Key Input

Explains how to input the license key required for Code Converter operation.

4 Using Data Exchange Code Converter

Data Exchange Code Converter User Process Flow

Illustrates the user's workflow for performing data conversion operations.

Database Data File Record Format

Describes the supported record formats and field positions for data files.

5 Mainframe to Open System (MTO) Character Code Conversion

Overview of Character Code Conversion

Introduces MTO conversion, including EBCDIC to ASCII and IBM Traditional Chinese to Big5.

Alphanumeric Field Conversion (CHAR:OPK4)

Details the specific conversion of alphanumeric fields in MTO.

6 Open System to Mainframe (OTM) Character Code Conversion

Overview

Introduces OTM conversion, including ASCII to EBCDIC and Big5 to IBM Traditional Chinese.

Customizing the Code Conversion Table

Explains how to customize the code conversion table for OTM.

7 Numeric Conversion

Packed Decimal Conversion (NUM:OPA1)

Details the conversion of packed decimal numeric data.

Zoned Decimal Conversion (NUM:OPA2)

Explains the process for converting zoned decimal numeric data.

8 Customizing the Code Conversion Table

Operation Overview

Provides a high-level overview of the code conversion table customization process.

Definition Statement Syntax

Describes the syntax rules for defining conversion statements used in customization.

Command Syntax for UNIX Systems

Explains the command syntax for customizing tables on UNIX systems.

9 Troubleshooting

Error Codes

Lists and explains common error codes and their meanings.

ccnv Messages

Details the format and interpretation of messages generated by the ccnv utility.

Calling HP Technical Support

Provides guidance on what information to gather before contacting HP support.

10 Support and Other Resources

Related Documentation

Lists other relevant HP documents for further information.

HP Technical Support

Information on how to obtain technical support from HP.

A Edit Option File

B HOSTBIG5

C EBCDIC-ASCII Code Conversion

Glossary

HP StorageWorks P9000 Specifications

General IconGeneral
RAID SupportRAID 0, 1, 5, 6, 10
InterfaceFibre Channel, iSCSI, FCoE
Form FactorRack-mountable
ModelP9000
Operating System CompatibilityWindows, Linux, VMware, HP-UX
Host InterfaceFibre Channel, iSCSI, FCoE
Drive InterfaceSAS, SSD
Drive Types SupportedSSD, SAS
RedundancyRedundant controllers, power supplies, and fans
Management SoftwareHP StorageWorks Command View

Related product manuals