Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 120.
Table 120 Format Stop Operation
DescriptionItem
The parity group number.PG
The number of parity groups.Num. of PGs
The LDEV number.LDEV
The number of LDEVs.Num. of LDEVs
Initialize ORM Value Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Initialize ORM Value,,Normal end,,,Seq.=xxxxx
[Install]
Install function
Initialize ORM Value
Initialize ORM Value operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Install Operation
Example 1 (installing additional channel adapters)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Install,,Normal end,,,Seq.=xxxxx
+{CHA,Kind}={CHA-1LU,16FS Fibre 8ch-4mp},
++{Port,Fibre PCB Mode,Initiator/Target,Channel Speed,CU Number}
=[{9J,Standard,Target,Auto,00:00-00:FE},{BJ,Standard,Target,Auto,00:00-00:FE},
-{DJ,Standard,Target,Auto,00:00-00:FE},{FJ,Standard,Target,Auto,00:00-00:FE},
{9K,Standard,Target,Auto,00:00-00:FE},{BK,Standard,Target,Auto,00:00-00:FE},
-{DK,Standard,Target,Auto,00:00-00:FE},{FK,Standard,Target,Auto,00:00-00:FE}],
Num. of Ports=8
+{CHA,Kind}={CHA-1KU, 8M MFibre 4ch-4mp},
++{Port,HTP/FNP,CU,Number,Emulation}=[{9N,HTP,00:00-00:3F,H-6591-2},
{BN,HTP,00:00-00:3F,H-6591-2},{DN,HTP,00:00-00:3F,H-6591-2},{FN,HTP,00:00-00:3F,
H-6591-2}],
Num. of Ports=4
+{CHA,Kind}={CHA-2XU,16FS Fibre 8ch-4mp},
++{Port,Fibre PCB Mode,Initiator/Target,Channel Speed,CU Number}
=[{AJ,Standard,Target,Auto,00:00-00:FE},{CJ,Standard,Target,Auto,00:00-00:FE},
-{EJ,Standard,Target,Auto,00:00-00:FE},{GJ,Standard,Target,Auto,00:00-00:FE},
{AK,Standard,Target,Auto,00:00-00:FE},{CK,Standard,Target,Auto,00:00-00:FE},
-{EK,Standard,Target,Auto,00:00-00:FE},{GK,Standard,Target,Auto,00:00-00:FE}],
Num. of Ports=8
Install Function160