7 BASE Function
Certificate Update Operation
user-name.xx,YYYY/MM/DD:HH:MM:SS.xxx,00:00,[BASE],Certificate Update,,Normal end,,,
Seq.=xxxx
+{File Name,Result}=[{server.crt,Normal end},{server.key,Error(XXX-XXXX)}]
[BASE]
BASE function
Certificate Update
Certificate Update operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 19.
Table 19 Certificate Update Operation
DescriptionItem
Name of the upload fileFile Name
Result of the upload operation
Normal end: normal end, Error (xxxx-yyyy): Abnormal end, -: not selected
xxxx: part code, yyyy: error code
Result
Control Panel Backup Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[BASE],Control Panel Backup,,Normal end,,,
Seq.=xxxxx
+{File Name,Result}=[{Storage Device List,Normal end},{User Account List,
Error(xxxx-yyyy)},{Environment Parameter List,-},{Audit Log Transfer Information,-}
[BASE]
BASE function
Control Panel Backup
Control Panel Backup operation
XP24000/XP20000 Audit Log User and Reference Guide 67