the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
LWAd
6.7 B
LpAm
51 dBA
Operating
LWAd
6.7 B
LpAm
51 dBA
Emissions Classification
Emissions ClassificationEmissions Classification
Emissions Classification
(EMC)
(EMC)(EMC)
(EMC)
FCC Rating
A
Normative Standards CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
NOTE:
NOTE:NOTE:
NOTE:
Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and
statements.
X1800
X1800X1800
X1800
System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(with bezel)
3.38 x 17.54 x 27.25 in (8.59 x 44.54 x 69.98 cm)
Weight
WeightWeight
Weight
(approximate)
Maximum
MaximumMaximum
Maximum
(all hard drives, power
supply, and processor
installed)
60 lb (27.22 kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
QuickSpecs
HP X1000 Network Storage Systems
HP X1000 Network Storage SystemsHP X1000 Network Storage Systems
HP X1000 Network Storage Systems
Technical Specifications
DA - 13341 North America — Version 16 — June 9, 2011
Page 49

Other manuals for HP X1000

Questions and Answers: