Duty cycle (Autorange)
Range Resolution Accuracy Sensitivity
Protection against
overcharge
0.5 - 99% 0.1%
(1.2%rdg + 2dgt)
>8Vrms 250VDC/ACrms
100s< pulse duration <100ms; Frequency range: 5Hz 150kHz
Note: in AC Voltage range, frequency range is: 10Hz 10kHz ; Sensitivity: > 15Vrms
Capacitance (Autorange)
Range Resolution Accuracy Protection against overcharge
40.00nF 0.01nF
(5.0%rdg + 7dgt)
250VDC/ACrms
400.0nF 0.1nF
(3.0%rdg + 5dgt)
4.000F 0.001F
40.00F 0.01F
100.0F 0.1F (5.0%rdg + 5dgt)
Temperature with K probe (Autorange)
Range Resolution Accuracy (*)
Protection against
overcharge
-20°C ÷ 400°C 0.1°C
(3.0%reading + 5°C)
250VDC/ACrms
400°C ÷ 760°C 1°C
-4°F ÷ 752°F 0.1°F
(3.0%reading + 9°F)
752F ÷ 1400°F 1°F
(*) Accuracy of the only instrument without probe