Installation for indoor unit
Indoor unit installation dimension drawing
Mounting plate
Wall bushing
1. The wall for installation of the indoor unit shall be
hard and rm, so as to prevent vibration.
2. Use the “+” type screw to fasten the peg board,
horizontally mount the peg board on the wall, and
ensure the lateral, horitontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to
conrm whether it is solid.
1. Once the position of the pipe pass has been
determined, make the hole in the wall, preferably with
a diamond crown, giving an outward slope of between
5º and 10º of inclination.
2. To prevent damage to the pipes, insulate them and
install trims on both sides of the wall to prevent leaks.
It is recommended to cover the pipe inside the wall
chamber with some product or element that prevents
rodents from leaving the pipe without insulation.
Putty
Pipe protection
ring
Space to
the wall
Space to
the ceiling
Space to the
wall
Space to
the wall
More than
20cm
More
than
15cm
More than
20cm