EasyManua.ls Logo

Huawei FusionServer G5500 - 3.6 Removing a GP316

Huawei FusionServer G5500
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
www.huawei.com Huawei Confidential 48
Asus: ESC8000 G3
Parameter G5500-G560 Asus ESC8000 G3
Dimensions (H x W x D)
4U (175*447*790) 3U (130.6*447*759)
Architecture Modular Integrated
CPU 2S + 24DIMM 2S + 24DIMM
Maximum CPU power 300 W 145 W
GPU 8*P100/P40 8*P100/P40
Maximum GPU power 350 W 300 W
CPU:GPU topology Flexible 1:8/1:4 Configuration 1:8 (1:4)
Hard drive
6*2.5'' NVMe SSD
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
6*2.5'' SATA SSD/HDD,
Supports SAS SSD/HH D when the PCIe RAID controller card is configured.
RAID RAID 0/1/10/5/50/6/60 PCH: RAID 0/1/10/5
When the PCIe RAID card is used: RAID 0/1/10/5/50/6/60
PCIe expansion 4*PCIe x16 1*PCIe x8 LP card. When the 8*dual-slot cards are not fully configured, 1*PCIe
x8 FHFL card can be configured.
On-board network adapter / 2*GE
Power supply 4*2200 W hot swap, 2+2 3*1600 W hot swap, 2+1
Fan 6 hot swap, 5+1 The built-in fans do not support hot swap. When the fan fails, heat dissipation is
affected.
Temperature
5°C to 35°C 10°C to 35°C
Beating Points
The integrated design of the chassis does not support independent evolution of the CPUs and GPUs.
The CPU:GPU topology is fixed and cannot be flexibly configured.
NVMe SSD is not supported. When the SAS drive is used, it needs to occupy the extended PCIe slot.
The 14 fans are built-in, and there are two types of fans, which require opening the chassis for maintenance.
Three 1600 W power modules do not support N+N redundancy, and the capacity expansion is limited and cannot be
evolved.
A large number of cables are connected inside the chassis, which is inconvenient for maintenance.