51
www.huawei.com Huawei Confidential 51
ASRock: 3U8G-C612/V
Parameter G5500-G560 ASRock 3U8G-C612/V
Dimensions (H x W x D)
4U (175*447*790) 3U
Architecture Modular Integrated
CPU 2S + 24DIMM 2S + 16DIMM
Maximum CPU power 300 W 145 W
GPU 8*P100/P40/P4 8*P100/P40/P4
Maximum GPU power 350 W 300 W
CPU:GPU topology 1:8/1:4 flexible configuration 1:8
Hard drive
6*2.5'' NVMe SSD
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
6*2.5'' SATA SSD/HDD
RAID RAID 0/1/10/5/50/6/60 ? (No RAID controller card?)
PCIe expansion 4*PCIe x16 1*PCIe x16 or 2*GE/10GE
On-board network adapter /
Power supply 4*2200 W hot swap, 2+2 4*1200 W hot swap, 3+1
Fan 6 hot swap, 5+1 The built-in does not support hot swap. When the fan
fails, heat dissipation is affected.
Temperature
5°C to 35°C 10°C to 35°C
Beating Points
The integrated design of the chassis does not support independent evolution of the CPUs and GPUs.
The CPU:GPU topology is fixed and cannot be flexibly configured.
Only 16 DIMMs are supported, and the memory capacity is limited.
NVMe SSD is not supported. (Without the RAID function)
The fans are built-in and require opening the chassis for maintenance.
The power capability is limited. The N+N redundancy cannot be supported when the power supply is fully loaded.