EasyManua.ls Logo

Huawei FusionServer Pro 2288X V5 - Page 42

Huawei FusionServer Pro 2288X V5
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Blinking at 4 Hz O Data is being read or written normally,
or data on the primary drive is being
rebuilt.
Steady on Blinking at 1 Hz The drive is being located.
Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is
being rebuilt.
O Steady on A member drive in the RAID array is
removed.
Steady on Steady on The drive is faulty.
NVMe Drive Indicators
Figure 5-29 NVMe drive indicators
If the VMD function is enabled and the latest VMD driver is installed, the
NVMe drives support surprise hot swap.
Table 5-9 Description of NVMe drive indicators (VMD enabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
O O The NVMe drive cannot be detected.
Steady on O The NVMe drive is working properly.
Blinking at 2 Hz O Data is being read from or written
to the NVMe SSD.
O Blinking at 2 Hz The NVMe drive is being located.
O Blinking at 8 Hz The data on the secondary NVMe
drive is being rebuilt.
Steady on/O Steady on The NVMe drive is faulty.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 36

Other manuals for Huawei FusionServer Pro 2288X V5