4.3 Conducted RF Measurement
4.3.1 Test Environment
R&S CMU200, R&S CMW500, Agilent E5515C, Starpoint
SP6010
KEITHLEY 2306, Aglient66319D
L08-C014-350 of DRAKA COMTEQ or Rosenberger
Cable length: 29 cm
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
4.3.2 Test Standards
Huawei modules meet 3GPP test standards. Each module passes strict tests at the
factory and thus the quality of the modules is guaranteed.
4.4 Conducted Rx Sensitivity and Tx Power
4.4.1 Conducted Receive Sensitivity
The conducted receive sensitivity is a key parameter that indicates the receiver
performance of ME909s Mini PCIe module. Table 4-3 and Table 4-4 list the typical
tested values of the typical Rx sensitivity.
Table 4-3 ME909s-821 Mini PCIe module conducted Rx sensitivity
Typical Value
(Unit: dBm)
FDD QPSK throughput > 95%, 10
MHz Bandwidth