Connecting Cables
7
Installing a PGND Cable
TO:
X-XXX-X-X
M8
M6
Installing DC Power Cables
Check the fuse capacity of the external power supply.
Device Model Recommended Fuse Capacity
NetEngine 8000 M14
PTN 6900-2-M14
NE40E-X2-M14
Device Model
NetEngine 8000 M14
PTN 6900-2-M14
NE40E-X2-M14
Maximum Cable Size
≥63A, ≤80A
(Select 10 mm² cables for 63 A circuit breakers,
and 16 mm² cables for circuit breakers
higher than 63 A.)
16mm², 10mm² (0-14meters) recommended,
16mm² (15-23meters) recommended