3.2 Powering Off the RRU
This describes how to power off the RRU and check the RRU status. The RRU power-off is
classified into normal power-off and emergency power-off.
Procedure
Step 1 Choose normal power-off or emergency power-off based on different situations.
If... Then...
The RRU needs to be powered off in the case
of an equipment swap or a foreseeable
regional blackout
Go to Step 2 to perform the normal power-
off.
An emergency such as an electric spark,
smoke, or water immersion occurs in the
RRU
Go to Step 3 to perform the emergency
power-off.
 
Step 2 Set the corresponding MCB on the auxiliary power device for the RRU to OFF.
NOTE
If RRU modules are cascaded, take the impact on the lower-level RRU module into consideration when
you power off an RRU module, so as to avoid disrupting ongoing services.
Step 3 Cut off the external input power of the auxiliary power device for the RRU. If time permits, set
the corresponding MCB on the device to OFF.
----End