CAUTION
l Take ESD protection measures before the installation, for example, wear ESD gloves or ESD
wrist strap.
l When installing multiple fan-free or intelligent-heat-dissipation devices in a cabinet or rack,
leave at least 1 U (1 U = 44.45 mm) distance between each two.
l Leave at least 50 mm clearance at two sides and rear of each chassis for heat dissipation.
l Preventing trips are required to fix AC terminals only in desk-mounting or wall-mounting,
and are not required in cabinet-mounting.
The S2700/3700/5700/6700 switches support the following installation scenarios:
l Desk-mounting
l Wall-mounting
l Cabinet- or rack-mounting
l Network box-mounting
Desk-Mounting
CAUTION
The S6700 chassis cannot be installed on a desk.
Before placing an S2700, S3700, S5700 chassis on a desk, attach rubber pads onto each of the
four recessed corner areas on the bottom of the chassis.
S2700&S3700&S5700&S6700 Series Ethernet Switches
Quick Start Guide 2 Device Installation
Issue 12 (2013-07-25) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5