7
Connecting the RS485 Communications Cable
4.5
Port
Identifier
COM1, COM2, COM3
+
It is recommended that the RS485 communication distance be less than or equal to 1000 m.
The SmartModule can connect to RS485 communications devices, such as a solar inverter, an
environmental monitoring instrument (EMI), and a power meter over the COM port.
Ensure that the RS485+ and RS485 terminals are respectively connected to the COM+ and
COM ports on the SmartModule.
Cascading Connection
You are advised to connect fewer than 30 devices to each RS485 route.
The baud rate, communications protocol, and parity mode of all devices on the RS485
cascading link must be the same as those of the COM ports on the SmartModule.