No. Parameter Description Remarks
23 Apparent power
baseline (kVA)
Adjust the apparent output
baseline of the inverter.
-
24 Active power
baseline (kW)
Adjusts the active output baseline
of the inverter.
-
25 Power percentage
for triggering Q-U
scheduling
Species the reference apparent
power, in percentage. When the
actual apparent power of the
inverter is greater than the value
of this parameter, the Q-U
characteristic curve scheduling
function is enabled.
-
26 Q-U characteristic
curve
The inverter adjusts Q/S (the ratio
of the output reactive power to
apparent power) in real time
based on U/Un(%) (the ratio of
the actual power grid voltage to
the rated power grid voltage).
-
27 Q-P characteristic
curve
The inverter adjusts Q/Pn (the
ratio of the output reactive power
to the rated active power) in real
time based on P/Pn(%) (the ratio
of the actual active power to the
rated active power).
-
28 Cosφ-P/Pn
characteristic curve
The inverter adjusts the output
power factor cosφ in real time
based on P/Pn(%).
-
7.2 Upgrading the Inverter
USB ash drives of SanDisk, Netac, and Kingston are recommended. Other brands
may be incompatible.
Delete the script le immediately after use to reduce information disclosure risks.
Procedure
Step 1 Download the required software upgrade package from the technical support
website.
Step 2 Decompress the upgrade package and copy all les to the root directory of the
USB ash drive.
SUN2000-(175KTL-H0, 185KTL-INH0, 185KTL-H1)
User Manual 7 Man-Machine Interactions
Issue 19 (2023-12-20) Copyright © Huawei Technologies Co., Ltd. 89