Clearance Requirements
Copyright © Huawei Digital Power Technologies Co., Ltd.
2023. All rights reserved.
The information in this document is subject to change due to version upgrade or other
reasons. Every effort has been made in the preparation of this document to ensure accuracy
of the contents, but all statements, information, and recommendations in this document do
not constitute a warranty of any kind, express or implied.
Only qualified and trained electrical technicians are allowed to operate the device. Operation
personnel should understand the system composition and working principles, as well as the
local regulations.
Before installing the device, read the user manual carefully to get familiar with product
information and safety precautions. Device damage caused by failure to abide by the
storage, transportation, installation, and operation guidelines specified in this document and
the user manual is not covered by the product warranty.
Before installing the device, check that the package contents are intact and complete against
the packing list. If any damage is found or any component is missing, contact your dealer.
Use insulated tools and wear proper personal protective equipment (PPE) when installing
the device.
If the installation clearance does not meet the requirements, the inverter power may be derated.
2
Device Installation
If cables are not connected immediately after the device is installed, you need to install a junction
box. Otherwise, the airtightness and waterproof performance of the device may be affected.

Other manuals for Huawei SUN2000-20KTL-M5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-20KTL-M5 and is the answer not in the manual?

Huawei SUN2000-20KTL-M5 Specifications

General IconGeneral
ModelSUN2000-20KTL-M5
TypeString Inverter
Max. DC Voltage1100 V
Start Voltage200 V
Nominal Input Voltage600 V
Max. Input Current per MPPT26 A
Number of MPPTs2
Rated AC Power20000 W
Max. Efficiency98.6%
Weight25 kg
Operating Temperature Range-25°C to +60°C
CoolingNatural convection
Protection DegreeIP66
AC Output Frequency50 Hz / 60 Hz
Max. DC Input Power30000 W
Max. Output Power22000 VA
Nominal Output Voltage230 Vac / 400 Vac
Rated AC Voltage400 V / 380 V / 220 V
AC Voltage Range320 V - 480 V
Dimensions (W x H x D)525 mm x 470 mm x 262 mm
Max. DC Power30, 000 W