N
o.
Parameter Description Remark
s
4 PV string N
access type
NOTE
N
is the DC input
terminal number
of the inverter.
Set this parameter based on the type of the
PV string connected to DC input terminal
N
of the inverter. Currently, the options are as
follows: Automatic identication (default
value), Disconnection, Single PV string,
and 2 in 1.
You are advised to retain the default value.
If the value is incorrectly set, the PV string
access type may be incorrectly
identied
and alarms may be generated by mistake
for the PV string connection status.
SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual B String Access Detection
Issue 07 (2021-07-08) Copyright © Huawei Technologies Co., Ltd. 112