Electronic Overspeed Switch EGS 40
EGS40_MANUAL-en_R6(2018-11-07)ID74528.docx
9.2 Test schedule
NOTE!
No interventions other than the cyclic tests described in the test schedule are necessary on
the device. Any intervention on the device renders all guarantee claims null and void!
Every 12 month (after app.
8000 operating hours)
Check the torque brackets (only for hollow
shaft devices): Check the link heads of the
torque brackets for ease of movement; link
rod must be capable of being turned by
hand. If movement is impaired, lightly oil the
link heads or treat them with glide spray.
Check the fastening screws for firm seat.
Check the cable connections
Perform a switch test (section 7.9, p. 22)
Every 2 to 3 years (after app.
20000 to 35000 operating
hours)
Check deep-groove ball bearing for ease of
movement and noise. Only have ball
bearings replaced by the manufacturer.
10 Disposal
The manufacturer is not obliged to take back the device.
The device is classed as electronic equipment and subject to the WEEE Directive; observe local,
country-specific laws when disposing of the device.
For information on environmentally sound disposal please contact your local authority or a specialist
disposal company.