Do you have a question about the Humminbird Matrix 10 and is the answer not in the manual?
Brand | Humminbird |
---|---|
Model | Matrix 10 |
Category | Fish Finder |
Language | English |
Details the 200 kHz single beam sonar system with a 200 area of coverage for Matrix models.
Explains the 200/83 kHz DualBeam PLUS212 sonar system with a wide 600 area of coverage.
Describes the QuadraBeam2 sonar with 900 coverage using 455 kHz beams for side structure.
Presents a historical log of sonar returns, displaying depth, temperature, and speed if available.
Increases display resolution to separate sonar returns that are close together.
Displays sonar returns from 83 kHz wide beam and 200 kHz narrow beam side-by-side.
Provides digital data in a large, easy-to-see format for depth, temperature, and speed.
Shows sonar information from left/right 900 455 kHz beams and 200 kHz down-looking beam.
Method where weak returns are dark pixels and strong returns are lighter pixels for visibility.
Represents weak returns as light pixels and strong returns as dark pixels for clarity.
Highlights strongest sonar returns in white for clear bottom definition.
Displays pixels below bottom contour as black, providing high contrast.
Used to turn the unit on/off and adjust backlight and contrast.
Cycles through all available views on the display.
Accessed during power-up to choose between Normal, Simulator, System Status, or PC Connect.
Provides quick access to frequently-used settings without navigating the full menu.
Organized system for accessing Alarms, Sonar, Setup, and Accessories.
Controls display detail by adjusting sonar return threshold for fish and debris.
Sets the shallowest depth range displayed in Sonar, Split Sonar, and Big Digits Views.
Sets the deepest depth range displayed, allowing manual depth selection.
Determines sonar information movement speed on display, affecting detail shown.
Selects display method for bottom and structure (Inverse, Structure ID2, WhiteLine1, Bottom Black).
Sets the magnification level for the Sonar Zoom View.
Sets which sonar returns from the transducer will be displayed on the screen.
Displays Fish Symbols when selective requirements are met, indicating fish size.
Adjusts Fish ID threshold to display weaker returns as fish.
Sets the Real Time Sonar window to Wide, Narrow, or Off.
Changes the sensitivity of the 83 kHz beam for weak returns.
Adjusts the sensitivity of the 455 kHz beam for weak returns.
Divides the display into four equal sections with horizontal depth lines.
Adjusts filter to remove surface clutter noise caused by algae and aeration.
Limits interference from sources like boat engine or turbulence.
Adjusts the maximum depth of operation for performance tuning.
Configures unit for operation in fresh or salt water for accurate readings.
Allows selection of the transducer to be used (QuadraBeam, WideSide).
Sounds when the depth becomes equal to or less than the set menu value.
Sounds when the system detects fish corresponding to the alarm setting (requires Fish ID+).
Sounds when input battery voltage drops below the set safety margin.
Selects the pitch of the alarm sound for best audibility.
Selects units of measure for all depth-related readouts (Meters, Feet, Fathoms).
Selects units of measure for temperature readouts (Celsius, Fahrenheit).
Selects units of measure for distance-related readouts (Miles, Kilometers, Nautical Miles).
Selects units of measure for speed-related readouts (kph, mph, kts).
Sets the menu system to Normal (basic) or Advanced (full control).
Selects the display language for menus (International Models Only).
Resets the Triplog data (elapsed time, distance, average speed) to zero.
Resets all menu settings to their factory defaults.
Sets available views to either hidden or visible in the view rotation.
Sets individual digital readouts in fixed-position data windows on the Sonar View.
Adjusts digital depth readout to indicate depth from waterline or keel.
Adjusts the temperature readout by the amount entered.
Adjusts the speed readout by a percentage entered.
Turns NMEA output on or off for data transmission.
Guidance for when the unit fails to power on, checking connections and fuse.
Troubleshooting steps when the system defaults to Simulator mode despite a connected transducer.