Do you have a question about the Humminbird Matrix 47 and is the answer not in the manual?
Display Size | 4.5 inches |
---|---|
Display Type | LCD |
GPS | No |
Target Separation | 2.5 inches |
Temperature | Yes |
Speed | Yes |
Backlight | Yes |
Sonar Type | Dual Beam |
Waterproof | Yes |
Sonar Frequency | 200 kHz |
Max Depth | 600 feet |
Depth Capability | 600 feet |
Mount Type | Gimbal |
Beam Angle | 20° / 60° |
Sonar Coverage | 60° / 20° |
Explains the 6-element transducer and its coverage for 3D terrain interpretation and fish location.
Explains the 2D sonar capability with 455 kHz and 83 kHz beams for depth and resolution.
Default view showing 3D representation of the bottom with boat position.
Displays historical sonar returns in a 2D format for structure and bottom hardness.
Displays 3D bottom terrain alongside traditional 2D sonar representation.
Increases display resolution to separate close sonar returns, splitting view into full and zoomed.
Method showing weak returns as dark pixels and strong returns as lighter pixels for clarity.
Represents weak returns as light pixels and strong returns as dark pixels for visibility.
Highlights strongest sonar returns in white to define the bottom clearly.
Controls power, backlight, and contrast for the unit.
Accesses the main menu system and X-Press™ Menu for settings.
Navigates menus, selects options, and controls view perspectives.
Menu accessed during power-up to select operating mode (Normal, Simulator, etc.).
Quick access menu for frequently-used sonar settings.
Organizes settings into Alarms, Sonar, Setup, Views, and Accessories tabs.
Magnifies the bottom image in 3D views for increased detail.
Sets the deepest depth range displayed in 3D views.
Determines sonar information speed and history displayed in 3D views.
Sets the width of the 2D sonar window in combo views.
Resets orientation, zoom, and range settings for 3D views.
Controls detail shown in the 6-Beam Sonar View.
Sets the shallowest depth range displayed in 2D views.
Sets the deepest depth range displayed in 2D views.
Determines sonar information movement speed and detail on display.
Selects display method for bottom and structure representation.
Sets magnification level for the 2D Zoom View.
Selects the visual style for the bottom in the 3D Sonar View.
Selects the frame style used for the bottom representation in the 3D Sonar View.
Sets which sonar returns from the transducer are displayed on the screen.
Interprets sonar returns to display fish symbols with depth information.
Adjusts the threshold for Fish ID detection algorithms.
Selects the reference line style used in the 3D Sonar View.
Controls the display of real-time sonar returns in 2D or 3D views.
Divides the display into four sections with horizontal depth lines.
Adjusts filter to remove surface clutter noise.
Limits interference from boat engine, turbulence, or other sonar sources.
Adjusts the maximum depth of operation for the fishing system.
Configures unit for operation in fresh or salt water for accuracy.
Sounds when the depth becomes equal to or less than the set menu value.
Sounds when the system detects fish corresponding to the alarm setting.
Sounds when battery voltage drops to or below the set menu threshold.
Selects the pitch of the alarm sound.
Selects the unit of measure for all depth-related readouts.
Selects unit of measure for temperature-related readouts (International Models).
Selects units for distance-related readouts when accessories are connected.
Sets menu system to Normal or Advanced for varying levels of control.
Resets the Triplog data for elapsed time, distance, and average speed.
Resets all menu settings to their factory default values.
Sets individual digital readouts displayed on the 3D or 2D Sonar View.
Adjusts digital depth readout to indicate depth from waterline or boat's keel.
Adjusts the temperature readout by a specified amount.
Adjusts the speed readout by a percentage entered.
Controls the visibility of the 2D Sonar View in the rotation.
Controls the visibility of the 3D Sonar View in the rotation.
Performs internal diagnostic self-test of the unit.
Guides to resolve issues where the system does not turn on.
Troubleshoots issues where the unit defaults to Simulator mode.