11 42934-01
Air Purier Maintenance
7. Place the Front Grill back onto the unit.
8. Plug in the Air Purier.
9. To reset the counter to zero hours and turn o the indicator, press and hold
the Pre-Filter & Carbon Odor Filter Reset Key for three seconds, then release
it.
10. To reset the Filter Life Counter to zero before it expires, press and hold the
Pre-Filter Reset Key for three seconds. When the Indicator begins ashing,
release the Key. Then, once again, press and hold the Pre-Filter Reset Key for
three seconds. The Indicator will turn o. The Counter is now reset to zero.
Changing the HEPAtech
®
Main Filter
When the HEPAtech
®
Main Filter exceeds 2800 hours (approximately 4 to 6 months of use),
the HEPAtech
®
Main Filter Indicator will turn on as a reminder that you should replace the
lter. Refer to Filter Life Counters for additional information, pg. 8. This is a reminder that
you should check the lter and replace it if necessary. The proper time to change the lter
depends on usage and the environment. Generally, if you notice a decrease in air output
or an increase in noise at any time during normal operation, the lter may be clogged.
Replace the lter to return to normal operation.
To change the lter and reset the Filter Life Counter:
1. First, turn o and unplug the Air Purier.
2. Next, remove the Front Grill. Place your ngers under the Grill Release Handle
and pull up. Refer to Figs. 4 and 5 (pg. 6).
3. Lift the Filter Tab and gently pull the lter out of the unit. Refer to Fig. 6. While
removing the lter, note the lter’s orientation - the new lter will be installed
with the same orientation. Refer to Fig. 10. Once removed, the used lter can
be discarded.
4. To install a new lter, position the lter with its rim facing the unit. Refer to
Fig. 10.
FILTER RIM
FILTER FRAME
Fig. 10