EasyManua.ls Logo

Hunter 44760 - Installation

Hunter 44760
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
12
INSTALLATION
TERMINAL FUNCTION
LABELS (HEAT PUMP) COMMENTS
R 24V AC supply Hot wire of 24VAC transformer. Powers the thermostat & system.
Y1 Compressor stage 1 Activates the 1st stage compressor. (Heat or Cool for Heat Pumps)
W2 Auxiliary heating Activates the 2nd stage (auxiliary) heating when required.
E Emergency heating
Activates Emergency heating ONLY when the System Switch is in Emergency (em) Mode.
O Reversing valve Activates reversing valve in COOL mode. ALWAYS ON in COOL MODE.
(cooling mode)
B Reversing valve Activates reversing valve in HEAT mode. ALWAYS ON in HEAT MODE.
(heating mode)
GFan Activates the system Fan. (Can be Auto, On, or Program controlled)
L System monitor Activates System Check LED on the front of thermostat.
(Controlled by the system, not the thermostat.)
C 24V AC common Common wire of 24V AC transformer. REQUIRED for thermostat operation.
TABLE A – TERMINAL DESCRIPTIONS
41652_model44760_web.pmd
13
13
TABLE B
HEAT PUMP CROSS-REFERENCE CHART
NOTE:
If your heat pump thermostat does not have an E wire, use the provided jumper wire to connect the E terminal to
the W2 terminal, as shown in three examples above. Refer to the Wiring Diagram on page 52.
EXAMPLES OF DIFFERENT SYSTEM TERMINALS
HUNTER BRYANT, RHEEM- TRANE,
TERMINALS CARRIER COLEMAN COMFORTMAKER PAYNE RUUD WEATHERTRON YORK LENNOX (1) LENNOX (2)
R RR R RRRRRV-VR
Y1 Y or Y1 Y Y Y Y Y Y Y M
W2 W2 W2 W1 W2 W2 W W W1 Y
E EEjumper E E X2 jumper E E
to W2 to W2
O OOOOOOR
B BB
G GG G GGGGGF
L L or F L L or X L L X L
C CXC, X, X1 C, C1, X1 X B B C X
Note: W2 wires Note: T wire
no connection no connection