EasyManua.ls Logo

Hunter H45DS - Page 140

Hunter H45DS
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H
unter 45
DS
• Waste and Sanitation S
y
stems
1
0.6
e
s involves locatin
g
the float switch and manuall
y
rotatin
g
th
e
fl
oa
t h
a
n
d
l
e
o
n th
e
s
i
de
o
f th
e
fl
oa
t
s
wit
c
h t
o
s
im
u
l
a
t
e
the
f
loat switch bein
g
underwater. This will ener
g
ize the
pump and the pump will operate.
1
0.5.1.2 Maintenance on bil
g
e pumps
N
o ma
i
ntenance
i
s requ
i
re
d
ot
h
er t
h
an ensur
i
n
g
t
h
at t
h
e
f
loat switches are operational and that there is no debris
c
lo
gg
in
g
the pump intakes
.
CAUTION
! !
R
unn
i
n
g
t
h
e macerator w
h
en t
h
e
h
o
ldi
n
g
tan
k
i
s
e
mpt
y
will cause dama
g
e to the pump
.
1
0.5.2 Macerator O
p
eration
1.
O
pen the macerator dischar
g
e valve
(
The dischar
g
e
va
l
ve
l
ocates
i
n ma
i
n
bilg
e
di
sc
h
ar
g
e compartment
by
inboard side o
f
g
alle
y)
.
2. Switch the “MACERAT
O
R” breaker on at the DC
P
anel.
(
The to
gg
le switch locates b
y
chart table
)
3
. Allow the macerator to run until the holdin
g
tank is
e
mpt
y
, but no lon
g
er.
4
.
Wh
en
y
ou
h
ear t
h
e pump spee
d
up,
i
n
di
cat
i
n
g
t
h
e
holdin
g
tank is empt
y
, immediatel
y
switch the pump o
ff
.
5
. Close the overboard dischar
g
e valve.
WARNING
! !
Failure to close the overboard dischar
g
e valve when
not in use could cause the holdin
g
tank to fill and
p
ossibl
y
flood the boat
.
WARNING
! !
Waste in the holdin
g
tank can form methane
g
as.
U
se suitable precautions when an
y
maintenance is
d
one to t
h
e san
i
tar
y
s
y
stem
.
1
0.5.2.1 Maintenanc
e
No maintenance is required on
y
our macerator pump
.
Helpful Hint: Should the macerator pump become clogged, you
can manually rotate the internal grinder wheels by removing
the small plastic cap on the back of the macerator pump. This
encloses the screw which is attached to the grinding wheels and
by inserting a flat screwdriver, you can rotate the wheels and
possibly remove any debris clogging the pump.
1
0.5.3 Shower Sum
p
The shower sump is controlled b
y
a rocker switch on the
vanit
y
face.
1
0.5.3.1 Maintenanc
e
Fi
g
. 10.3
g
ives
y
ou an idea o
f
how to remove the plastic
c
over on the shower sump. While no maintenance is
required on the pump itself,
y
ou do need to ensure that
the holdin
g
tank is clean and
f
ree o
f
debris
f
or the opera-
tion to be functional.
(
See
O
EM packet that comes with
o
wner’s manual packet
)
1
0.5.4 Holdin
g
Tank
The holdin
g
tank must be cleaned or pumped out when it
becomes nearl
y
full. There are two methods for removin
g
waste from the holdin
g
tank, either b
y
pumpin
g
overboard
in coastal waters, or b
y
dockside pump-out at a waste
facilit
y
.
1
0.5.4.1 Overboard Pum
p
-out O
p
eration
S
ee the macerator operation
g
uide, Section 10.5.2, for
instructions on how to pump out the holdin
g
tank
.
Important: U.S. Coast Guard regulations require that boats
have a sanitation system on board to control pollution. Waste
is to be stored in a holding tank or other device so it can be
properly disposed of at a shore facility. Discharging this waste
overboard in U.S. lakes, rivers, bays, and sounds and within 3
miles of shore in international waters is prohibited. Check with
the Coast Guard regarding regulations in your area.
1
0.5.4.2 Dockside Waste Removal
To remove waste from the holdin
g
tank at a dockside
waste
f
acilit
y
, insert the hose
f
rom the pump-out
f
acilit
y
into the waste access on the coamin
g
(
Fi
g
. 10.8
)
o
f
y
our
boat and follow instructions at the facilit
y
. Instructions
f
rom one
f
acilit
y
to another ma
y
var
y
.

Table of Contents

Related product manuals