ALIGNING THE RIGHT (FIXED) SIDE OF ARC
If the right side of the arc is not properly aligned, the results may be a wet walkway
or a dry turf area. The right side arc can easily be realigned. One way to realign
the right stop is to turn the whole sprinkler body assembly and the fitting below
it, left or right to the desired position. This may require temporary removal of the
soil around the sprinkler to allow you to grip the sprinkler housing.
Another way to reset the right arc is to unscrew the body cap counterclockwise
and remove the internal assembly from the body. Once removed, rotate the nozzle
turret to the right stop, screw the internal assembly back into the body with the
nozzle aligned to the right side of the area you want irrigated (Fig. 9). At this point
you have realigned the right arc stop, and you can adjust the left arc to an
appropriate setting.
Note:
It is not necessary to dig up and remove the whole sprinkler to realign the
right arc.
NOZZLE INSTALLATION
1. Insert the plastic key end of the Hunter wrench into the lifting socket of the
sprinkler and turn 90°. Pull the riser up to gain access to the nozzle socket
(Fig. 8).
2. Using the hex key of the Hunter wrench, turn the radius adjustment screw
(Fig. 6) counterclockwise to be sure it is not blocking the nozzle socket opening.
If a nozzle is already installed, it can be removed by backing out the adjustment
screw and turning on the water, or by pulling outward on the nozzle “ears” with
a pair of needle-nosed pliers.
3. Slip the desired nozzle into the nozzle socket (Fig. 7). Note that the socket is
angled up 25°. The “ears” should be
adjusted so that the nozzle range
screw threads directly down between
them. Then tighten the nozzle range
screw. The raised bump with an arrow
on the rubber cover will always indicate
the location of the nozzle and direction
of water flow when the sprinkler is
retracted.
®
Professional Series™
PGP
®
, PGS, PGH
Gear-Driven Sprinklers
Fig. 8
P
G
P
®
Fig. 9
®
Fig.7
Note: All precipitation rates calculated for 180 degree operation.
For the precipitation rate for a 360 degree sprinkler, divide by 2.
PGP Standard Nozzle (Red) Performance
Data – Metric
Pressure Radius Flow Precip mm/hr
Nozzle Bars kPa m m
3
/hr l/min
1
2.1
2.8
3.4
4.1
206
275
344
413
8.5
8.8
8.8
9.1
0.11
0.14
0.16
0.18
1.9
2.3
2.7
3.0
3
3
4
4
4
4
5
5
2
2.1
2.8
3.4
4.1
206
275
344
413
8.8
9.1
9.1
9.4
0.16
0.18
0.20
0.23
2.6
3.0
3.4
3.8
4
4
5
5
5
5
6
6
3
2.1
2.8
3.4
4.1
206
275
344
413
9.1
9.4
9.4
9.8
0.20
0.23
0.27
0.30
3.4
3.8
4.5
4.9
5
5
6
6
6
6
7
7
4
2.1
2.8
3.4
4.1
206
275
344
413
9.8
10.1
10.4
10.4
0.27
0.32
0.36
0.41
4.5
5.3
6.1
6.8
6
6
7
8
7
7
8
9
5
2.1
2.8
3.4
4.1
206
275
344
413
10.4
11.0
11.6
11.6
0.36
0.41
0.45
0.50
6.1
6.8
7.6
8.3
7
7
7
7
8
8
8
9
6
2.1
2.8
3.4
4.1
206
275
344
413
11.0
11.6
12.2
12.2
0.45
0.55
0.61
0.66
7.6
9.1
10.2
11.0
8
8
8
9
9
9
10
10
7
2.1
2.8
3.4
4.1
206
275
344
413
11.0
12.2
12.8
12.8
0.59
0.68
0.77
0.84
9.8
11.4
12.9
14.0
10
9
9
10
11
11
11
12
8
2.1
2.8
3.4
4.1
206
275
344
413
11.3
12.2
13.1
13.4
0.73
0.84
0.95
1.04
12.1
14.0
15.9
17.4
11
11
11
12
13
13
13
13
9
2.1
2.8
3.4
4.1
206
275
344
413
11.6
13.1
14.0
14.3
0.95
1.11
1.25
1.36
15.9
18.5
20.8
22.7
14
13
13
13
16
15
15
15
10
2.8
3.4
4.1
4.8
275
344
413
482
13.7
14.6
14.9
15.5
1.36
1.54
1.73
1.86
22.7
25.7
28.8
31.0
14
14
15
15
17
17
18
18
11
2.8
3.4
4.1
4.8
275
344
413
482
14.0
14.6
15.2
15.5
1.82
2.02
2.23
2.39
30.3
33.7
37.1
39.7
18
19
19
20
21
22
22
23
12
2.8
3.4
4.1
4.8
275
344
413
482
14.0
14.6
15.2
15.9
2.59
2.77
3.00
3.27
43.1
46.2
50.0
54.5
26
26
26
26
30
30
30
30
PGP Low Angle Nozzle (Gray) Performance Data
Pressure Radius Flow Precip in/hr
Nozzle PSI ft. GPM
4
30
40
50
60
22'
24'
26'
28'
1.4
1.7
1.8
2.0
0.56
0.57
0.51
0.49
0.64
0.66
0.59
0.57
5
30
40
50
60
25'
27'
28'
30'
1.6
1.9
2.1
2.3
0.49
0.50
0.52
0.49
0.57
0.58
0.60
0.57
6
30
40
50
60
27'
30'
33'
35'
2.1
2.5
2.8
3.0
0.55
0.53
0.49
0.47
0.64
0.62
0.57
0.54
7
30
40
50
60
29'
32'
35'
37'
2.8
3.1
3.5
3.8
0.64
0.58
0.55
0.53
0.74
0.67
0.64
0.62
8
30
40
50
60
31'
34'
37'
38'
3.4
3.9
4.4
4.7
0.68
0.65
0.62
0.63
0.79
0.75
0.71
0.72
9
30
40
50
60
33'
37'
40'
42'
4.3
5.0
5.6
6.1
0.76
0.70
0.67
0.67
0.88
0.81
0.78
0.77
10
40
50
60
70
38'
40'
42'
44'
6.5
7.3
8.0
8.6
0.87
0.88
0.87
0.86
1.00
1.01
1.01
0.99
P
Blank nozzle plug for turning off selected sprinklers
during repairs, maintenance, etc.
PGP Standard Nozzle (Red) Performance Data
Pressure Radius Flow Precip in/hr
Nozzle PSI ft. GPM
1
30
40
50
60
28'
29'
29'
30'
0.5
0.6
0.7
0.8
0.12
0.14
0.16
0.17
0.14
0.16
0.19
0.20
2
30
40
50
60
29'
30'
30'
31'
0.7
0.8
0.9
1.0
0.16
0.17
0.19
0.20
0.19
0.20
0.22
0.23
3
30
40
50
60
30'
31'
31'
32'
0.9
1.0
1.2
1.3
0.19
0.20
0.24
0.24
0.22
0.23
0.28
0.28
4
30
40
50
60
32'
33'
34'
34'
1.2
1.4
1.6
1.8
0.23
0.25
0.27
0.30
0.26
0.29
0.31
0.35
5
30
40
50
60
34'
36'
38'
38'
1.6
1.8
2.0
2.2
0.27
0.27
0.27
0.29
0.31
0.31
0.31
0.34
6
30
40
50
60
36'
38'
40'
40'
2.0
2.4
2.7
2.9
0.30
0.32
0.32
0.35
0.34
0.37
0.38
0.40
7
30
40
50
60
36'
40'
42'
42'
2.6
3.0
3.4
3.7
0.39
0.36
0.37
0.40
0.45
0.42
0.43
0.47
8
30
40
50
60
37'
40'
43'
44'
3.2
3.7
4.2
4.6
0.45
0.45
0.44
0.46
0.52
0.51
0.50
0.53
9
30
40
50
60
38'
43'
46'
47'
4.2
4.9
5.5
6.0
0.56
0.51
0.50
0.52
0.65
0.59
0.58
0.60
10
40
50
60
70
45'
48'
49'
51'
6.0
6.8
7.6
8.2
0.57
0.57
0.61
0.61
0.66
0.66
0.70
0.70
11
40
50
60
70
46'
48'
50'
51'
8.0
8.9
9.8
10.5
0.73
0.74
0.75
0.78
0.84
0.86
0.87
0.90
12
40
50
60
70
46'
48'
50'
52'
11.4
12.2
13.2
14.4
1.04
1.02
1.02
1.03
1.20
1.18
1.17
1.18
PGP Low Angle Nozzle (Gray) Performance
Data – Metric
Pressure Radius Flow Precip mm/hr
Nozzle Bars kPa m m
3
/hr l/min
4
2.1
2.8
3.4
4.1
206
275
344
413
6.7
7.3
7.9
8.5
0.32
0.39
0.41
0.45
5.3
6.4
6.8
7.6
14
14
13
12
16
17
15
14
5
2.1
2.8
3.4
4.1
206
275
344
413
7.6
8.2
8.5
9.1
0.36
0.43
0.48
0.52
6.1
7.2
7.9
8.7
13
13
13
12
14
15
15
14
6
2.1
2.8
3.4
4.1
206
275
344
413
8.2
9.1
10.1
10.7
0.48
0.57
0.64
0.68
7.9
9.5
10.6
11.4
14
14
13
12
16
16
15
14
7
2.1
2.8
3.4
4.1
206
275
344
413
8.8
9.8
10.7
11.3
0.64
0.70
0.80
0.86
10.6
11.7
13.2
14.4
16
15
14
14
19
17
16
16
8
2.1
2.8
3.4
4.1
206
275
344
413
9.4
10.4
11.3
11.6
0.77
0.89
1.00
1.07
12.9
14.8
16.7
17.8
17
16
16
16
20
19
18
18
9
2.1
2.8
3.4
4.1
206
275
344
413
10.1
11.3
12.2
12.8
0.98
1.14
1.27
1.39
16.3
18.9
21.2
23.1
19
18
17
17
22
21
20
20
10
2.8
3.4
4.1
4.8
275
344
413
482
11.6
12.2
12.8
13.4
1.48
1.66
1.82
1.95
24.6
27.6
30.3
32.6
22
22
22
22
25
26
26
25
P
Blank nozzle plug for turning off selected sprinklers
during repairs, maintenance, etc.

Other manuals for Hunter Professional Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hunter Professional Series and is the answer not in the manual?

Hunter Professional Series Specifications

General IconGeneral
DisplayLCD
Sensor CompatibilityRain
EnclosureWeatherproof
Warranty2 years
MaterialPlastic
ColorBlack
Zones4, 6, 8, 12, 14, 22, 24 (depending on model)