EasyManuals Logo

Hunter SET & SAVE 44155C User Manual

Hunter SET & SAVE 44155C
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
50
5. My heating or cooling will not turn on or off.
5 a. Check the Heat/Cool function switch to ensure it is set to
the desired position.
5 b. Wait. There may be as much as a 4-minute delay before
the system turns on or off to protect the compressor.
5 c. Check the circuit breakers and switches to ensure there
is enough power to the system.
5 d. Replace the batteries.
5 e. If applicable, make sure the furnace blower door is
closed properly.
5 f. If your system has 4 wires, ensure the jumper wire is
installed between the RC and RH terminals.
....................................................................................
6. The display will come on, but it will not stay
illuminated.
6 a. Replace batteries.
TROUBLESHOOTING