SAFETY EQUIPMENT
14 English
Remove the chain and guide bar. See instruction book.
Inspect the chain catcher and replace it if it is damaged.
Tighten the retaining bolts to 6 Nm. See fig. 8.
Refit chain and guide bar. See instruction book.
Silencer
Fig. 8
Fig. 11
Stop switch
Dismantling
Prise out the stop switch with the help of a screwdriver and
detach the leads. See fig. 10.
!
WARNING!
Do not touch the silencer before it has
cooled. Risk for burns.
Dismantling
1. Remove the two M5-bolts and the two M6-bolts and lift off
the silencer and silencer mount. See fig. 9.
2. Remove the gasket and cooling plate. See fig. 9.
3. If the saw is equipped with a spark guard, this should be
removed. See fig. 9.
Fig. 9
Fig. 10
Chain catcher
Inspection
Clean all components and check the following:
1. The spark guard is undamaged.
2. The silencer and silencer mount are not cracked or have
any other defects.
3. The gasket is undamaged.
Reassembly
1. Clean the gasket, cooling plate and cylinder contact
surfaces.
2. If the chainsaw is equipped with a spark guard, refit it.
See fig. 9.
3. Locate the cooling plate, gasket and silencer against the
cylinder. Tighten the two M6-bolts to 14 Nm. Tighten the
two M5-bolts to 10 Nm.
Inspection
Measure the resistance by connecting an ohmmeter to the
stop switch. See fig. 11. The resistance should be as follows:
0 pressed in - less than 0.1 .
1 pressed in - more than 1000 .
Reassembly
Push on the leads and press the stop switch into the slot in
the tank unit.