To do a check of the ground fault circuit interrupter
1. Connect the power plug of the product into the mains
outlet.
2. Push the RESET button (A). The power indicator (B)
becomes green.
3. Push the TEST button (C). The power indicator goes
off and the fault indicator (D) becomes red. The
product cannot be started. If the fault indicator does
not comes on, speak to your Husqvarna service
agent.
4. Start the product. Refer to
To start the product on
page 19
.
5. Reset with the RESET button. The power indicator
becomes green.
6. If the product does not start, speak to your
Husqvarna service agent.
Blade guard
WARNING:
Do not use the product
without a blade guard or with a defective
blade guard. Make sure that the blade guard
is installed and attached correctly before you
start the product.
The blade guard prevent parts, of the blade or the
material that is cut, to be thrown at the operator.
To do a check of the blade guard
• Make sure that the blade guard is correctly installed
and attached. Refer to
To install the blade guard on
page 15
.
• Examine the blade guard for damages, such as
cracks.
• Replace a damaged blade guard.
• Replace the blade guard if it is hit, bent or has other
defects.
Drive belt cover
WARNING: Do not use the product
without a drive belt cover or with a defective
drive belt cover. Make sure that the drive
belt cover is installed and attached correctly
before you start the product.
The drive belt cover gives protection from the pulleys
and the drive belt.
To do a check of the drive belt cover
• Make sure that the drive belt cover is not damaged
or has cracks. Replace the drive belt cover if it is
necessary.
• Make sure that the 2 screws of the drive belt cover
are installed and correctly tightened.
Safety instructions for maintenance
• Keep all parts in good condition and make sure that
all fixtures are correctly tightened.
• Do not use a product that is defective. Do the safety
checks, maintenance and the servicing as given in
1620 - 003 - 28.02.2022
11