HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
RLN with Innovator Doors Technical Data Sheet
2 of 6
5
3
/8
(142)
C
A
B
Front
5-Door Shown
6
(152)
(see note *)
Water Seal (see note **)
30
5
/8
(778)
35
3
/8
(899)
39
3
/4
(1010)
28
(711)
37
5
/8
(954)
Refrig. Outlet
Electrical Wireway
37
5
/8
(954)
Bottom Front
Support
48
(1219)
3 (76)
4 (102)
Waste Outlet
Relay & Terminal
Block Location
Skid/External Base
Reach-in Narrow
2, 3, 4, & 5 Door
10/2001
Engineering
Plan Views
RLN & RMN
Plan View
3 (76)
4 (102)
D
Dimensions shown as in. & (mm).
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Case Length (without ends or partitions) 62 (1575) 92
1
/2 (2350) 122
7
/8 (3121) 153
3
/8 (3896)
Maximum O/S dimension of case back to front 39
3
/4 (1010) 39
3
/4 (1010) 39
3
/4 (1010) 39
3
/4 (1010)
(Includes bumper)
Back of case to rear of splashguard 35
3
/8 (899) 35
3
/8 (899) 35
3
/8 (899) 35
3
/8 (899)
Width of Skidrail 4
1
/2 (114) 4
1
/2 (114) 4
1
/2 (114) 4
1
/2 (114)
Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152)
Stub-up area between front skidrail and splashguard 6
3
/8 (1000) 6
3
/8 (1000) 6
3
/8 (1000) 6
3
/8 (1000)
Electrical Service
RH end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102)
(B) RH end of case to the center of LH knockout 58 (1473) 88
1
/2 (2248) 118
7
/8 (3019) 149
3
/8 (3794)
Back O/S of case to center of knockout 37
5
/8 (956) 37
5
/8 (956) 37
5
/8 (956) 37
5
/8 (956)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(C) Right end of case to center of waste outlet 23
3
/4 (603) 54
1
/4 (1378) 46
1
/4 (1175) 76
5
/8 (1946)
Back O/S of case to center of waste outlet 34
5
/8 (879) 34
5
/8 (879) 34
5
/8 (879) 34
5
/8 (879)
Water Seal
Edge of water seal to center of waste outlet 11 (279) 11 (279) 11 (279) 11 (279)
Outside diameter of drip piping 1
1
/4 (32) 1
1
/4 (32) 1
1
/4 (32) 1
1
/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 5
3
/8 (137) 5
3
/8 (137) 5
3
/8 (137) 5
3
/8 (137)
Back O/S of case to center of refrigeration outlet 28 (711) 28 (711) 28 (711) 28 (711)
(D) Outside bottom front supports from end of case 6
3
/4 (170) 6
3
/4 (170) 6
3
/4 (170) 6
3
/4 (170)
Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Distance between Center and Outside supports will vary
01-2003