9
Case Specifications
REFRIGERATED SECTION
BTU DISC T-STAT TYPE & FAN DEFROST
REQ TEMPERATURE AIR MODEL MAKE BLADE FREQ CIRC. 1 CIRC. 3 SELF CONTAINED INFO.*
LENGTH PER EVAP CASE DISC VELOC & EVAP & SIZE (") & & QTY AMPS SHELF RECEP Low Pressure AMP-
FT TMP TMP TMP @FPM SETTINGS SETTING PITCH ° DURATION FANS FANS LEVELS LIGHTS TACLE Control & Setting HP VOLTS ACITY
R3P Prep Top (Front Refrigerated Section Only)
4' 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 2 .36 2 1.73 15.0 50 in 1/3 115 10.9
Air (2) (4) 30 out
6' 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 4 .72 2 1.73 15.0 50 in 3/4 208 8.7
Air (4) (4) 30 out ~230
8' 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 4 .72 2 2.85 15.0 50 in 1 208 13.0
Air (4) (4) 30 out ~230
10' 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 6 1.08 2 3.97 15.0 50 in 1 208 13.0
Air (6) (4) 30 out ~230
12' 650 15° 36° 24° 250 EPR Forced 4
1
/2"Axial 40 min. 6 1.08 2 4.48 15.0 50 in 1 208 13.0
Air (6) (4) 30 out ~230
R3P Prep Top with Refrigerated Rear Storage (Front Refrigerated Section)
4' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 2 .36 2 1.73 15.0 50 in 1/2 115 19.9
Air (2) (4) 30 out
Rear Storage 175 15° 36° 30° 125 35° Forced 5
1
/4" X 30° 40 min. 1 1.10 2 1.73 15.0
Air (1) (4)
6' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 4 .72 2 1.73 15.0 50 in 3/4 208 8.7
Air (4) (4) 30 out ~230
Rear Storage 175 15° 36° 30° 125 35° Forced 5
1
/4" X 30° 40 min. 1 1.10 2 1.73 15.0
Air (1) (4)
8' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 4 .72 2 2.85 15.0 50 in 1 208 13.0
Air (4) (4) 30 out ~230
Rear Storage 175 15° 36° 30° 125 35° Forced 5
1
/4"X 30° 40 min. 2 2.20 2 2.85 15.0
Air (2) (4)
10' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2"Axial 40 min. 6 1.08 2 3.97 15.0 50 in 1
1
/2 208 19.0
Air (6) (4) 30 out ~230
Rear Storage 175 15° 36° 30° 125 35° Forced 5
1
/4" X 30° 40 min. 2 .90 2 3.97 15.0
Air (2) (4)
12' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 6 1.08 2 4.48 15.0 50 in 1
1
/2 208 19.0
Air (6) (4) 30 out ~230
Rear Storage 175 15° 36° 30° 125 35° Forced 5
1
/4" X 30° 40 min. 2 .90 2 4.48 15.0
Air (2) (4)
R3 Service Top (Front and Top Section - Dry Rear Storage)
4' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 2 .36 2 1.73 15.0 50 in 1/2 115 19.9
Air (2) (4) 30 out
Top 250 15° 36° 24° 125 24° Forced 3" Axial 40 min. 2 .32 2 1.73 15.0
Air (2) (4)
6' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 4 .72 2 2.24 15.0 50 in 1 208 13.0
Air (4) (4) 30 out ~230
Top 250 15° 36° 24° 125 24° Forced 3" Axial 40 min. 4.64 2 2.2415.0
Air (4) (4)
8' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2"Axial 40 min. 4 .72 2 3.36 15.0 50 in 1/3 208 13.0
Air (4) (4) 30 out ~230
Top 250 15° 36° 24° 125 24° Forced 3" Axial 40 min. 4 .64 2 3.36 15.0
Air (4) (4)
10' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 61.08 2 5.09 15.0 50 in 1/3 208 19.0
Air (6) (4) 30 out ~230
Top 250 15° 36° 24° 125 24° Forced 3" Axial 40 min. 6 .96 2 5.09 15.0
Air (6) (4)
12' Front 650 15° 36° 24° 250 EPR Forced 4
1
/2" Axial 40 min. 6 1.08 2 5.60 15.0
Air (6) (4)
Top 250 15° 36° 24° 125 24° Forced 3" Axial 40 min. 6 .96 2 5.60 15.0
Air (6) (4)
NOTES: These refrigerated merchandisers have been designed for use in stores where temperatures and humidity are maintained at or below 75°F and 55%RH. Stores are responsible for setting
their cases appropriately in conditions which vary from the above. The number of defrosts and/or the duration may vary for cases displaying products for which they were not designed.
Italicized data indicates optional equipment.
* In Self contained units, 4' of the Rear Storage area is occupied by the Condensing Unit