Do you have a question about the Hyco SF15K and is the answer not in the manual?
Brand | Hyco |
---|---|
Model | SF15K |
Category | Water Heater |
Language | English |
Essential safety warnings for installation and operation, including competent person installation and water filling.
Ensure the mounting surface can support the heater's weight, including water.
Fit the 6 bar relief valve correctly and use ½" BSP fittings, colour-coded for hot/cold. Clear airlocks by running water.
Comply with IEE regs, use fused spur, earth the unit, and ensure it's full of water before power.
Neon lamp indicates heating. Use lowest temp setting for energy saving and limescale reduction.
Hot water poses a scalding risk; a blending valve is recommended for high-risk situations.
Disconnect power before maintenance. Reset thermal cutout by pressing the button.
Inspect anode annually for corrosion. Check pressure relief valve annually for water discharge.
Addresses issues like water flow from relief valve, no hot water, low volume, and leaks.
Details on supply, power, tank capacity, material, dimensions, pressure relief setting, and thermal cutout.
One-year guarantee against faults. Provides company contact details for support and service.